Operating instructions
Swim Spa Operator’s Guide
12
Note: The white neutral wire from the back of the GFCI MUST be connected to an incoming
line neutral. The internal mechanism of the GFCI requires this neutral connection. The
GFCI will not work without it.
NOTE!
(XM) WIRING DIAGRAM - 12’
THE DIAGRAM IS INTENDED FOR THE XM PACK SYSTEM
Wiring Requirements
• 2-Hots, 1-Neutral, 1-Isolated Ground
• 0-40’ length, 4 Wire #6 AWG minimum 75˚C copper conductor
• Over 40’ length, 4 Wire #6 AWG minimum 75˚C copper conductor
(Check your local Electrical codes for 60 Amp GFCI circuits for correct wire size for some areas
vary)
Factory Recommended G.F.C.I. Load Center Wiring
Note: Connection order may vary by pack model, please refer to equipment pack panel
for proper connection order.