Operating instructions
Swim Spa Operator’s Guide
TROUBLE SHOOTING GUIDE
No heat or heat too low
Probable Cause #1 ....... Dirty Filter.
Action ........................... Remove filter cartridge and clean.
Probable Cause #2 ....... Breaker at house off.
Action ........................... Reset breaker at house. Breaker can appear to be on and one pole can
be off. Turn breaker OFF then ON twice.
Probable Cause #3 ....... Pump not primed.
Action ........................... Refer to the section of this manual on pump priming.
Probable Cause #4 ....... Improper line voltage.
Action ........................... Have a Licensed Electrician check the line voltage.
Pump will not prime
Probable Cause #1 ........ No water in pump.
Action ............................ Make sure water level in spa is correct.
Probable Cause #2 ........ Closed gate valves or blocked lines.
Action ............................ Open all gate valves. Check suction for blockage.
Probable Cause #3 ........ Pump surges, jets lose and gain power, loose union or drain plug.
Action ............................ Check union on front or nose of pump to ensure tightness. Check drain
plugs to ensure tightness.
Jet(s) won’t come on
Probable Cause #1 ........ Pump not primed.
Action ............................ Refer to the section of this manual on pump priming.
Probable Cause #2 ........ Gates valves closed.
Action ............................ Check to see if gate valves are in the correct position. Check to see that
pump is plugged in.
Probable Cause #3 ........ Water Diverter Valve not adjusted correctly.
Action ............................ Turn Water Diverter Valve until desired water flow is obtained.
Probably Cause #4 ........ Individual jet is closed.
Action ............................ Turn the outer jet housing clockwise to turn jet on.
Low water flow
Probable Cause #1 ........ Dirty Filter.
Action ............................ Remove filter cartridge and clean.
Probable Cause #2 ........ Closed gate valves or blocked lines.
Action ............................ Open all gate valves.
Probable Cause #3 ........ Low voltage or incorrect voltage.
Action ............................ Have a Licensed Electrician check the line voltage.
40