Operating instructions

Swim Spa Operators Guide
Note: The white neutral wire from the back of the GFCI MUST be connected to an incoming
line neutral. The internal mechanism of the GFCI requires this neutral connection. The
GFCI will not work without it.
(XM) WIRING DIAGRAM - 12’
THE DIAGRAM IS INTENDED FOR THE XM PACK SYSTEM
Wiring Requirements
• 2-Hots, 1-Neutral, 1-Isolated Ground
• 0-40’ length, 4 Wire #6 AWG minimum 75˚C copper conductor
• Over 40’ length, 4 Wire #6 AWG minimum 75˚C copper conductor
(Check your local Electrical codes for 60 Amp
GFCI circuits for correct wire size for some areas vary)
Factory Recommended G.F.C.I. Load Center Wiring
Note: Connection order may vary by pack model, please refer to equipment pack panel
for proper connection order.
The XM Pack require 230volts for operation
1 L
N
2 L
G
Heater communiaction
Speaker lift control
Circ. Pump
TV Lift control
Ozone
12 volt Power Supply
Light Communication
Top Side Controls (Aux or Main)
Top Side Controls (Aux or Main)
Accessory connector
I/O connector
Pump 3
Pump 2
Pump 1
1 L
N
2 L
G
Heater communiaction
Circ. Pump (if required)
Ozone
12 volt Power Supply
Light connector
Top Side Controls (Aux or Main)
Top Side Controls (Aux or Main)
Accessory connector
I/O connector
Pump 3
Pump 2
Pump 1
Power connection for Heater
CINEMA SERIES SPAS
Non - CINEMA SERIES SPAS
Blower (if required)
XM Spa Packs
Speaker Lift (if required)
Power connection for Heater
1 L
N
2 L
G
(White Wire
To the Spa)
l i a t g i P e t i h W
White Pigtail
Neutr
al Bar
r a B l a r t u e N
a p S m o r F e t i h W
Spa
Wiring Requirements:
• 2-Hots, 1-Neutral, 1-Isolated Ground
• 0-40 length, 4 Wire #6 AWG copper conductor
Over 40 length, 4 Wire #4 AWG copper conductor
Note: The white neutral wire from the back of the GFCI MUST be
connected to an incoming line neutral. The internal mechanism of
the GFCI requires this neutral connection. The GFCI will not work
without it.
ATTENTION!
IMPROPER WIRING WILL VOID WARRANTY
To:
(Check your local Electrical codes for 60 Amp GFI circuits
for correct wire size for some areas varry)
1 L
N
2 L
G
3 L
1 L
N
2 L
G
3 L
1 L
N
2 L
G
3 L
When using three phase power
Pack settings should be:
Ph = 3
Br = 16 (amp)
Remove Jumper
When using two line power
connect First line to L1
and the second to L2 & L3
using Jumber with tab removed.
Pack settings should be:
Ph = 2
Br = 16 (amp)
When using single line
use jumper provided and connected
to L1, L2 & L3
Pack settings should be:
Ph = 1
Br = 32 (amp)
XM.ce 50 Hz Hook-up information
60 Hz 230 volts
The XM Pack require 230volts for operation
1 L
N
2 L
G
Heater communiaction
Speaker lift control
Circ. Pump
TV Lift control
Ozone
12 volt Power Supply
Light Communication
Top Side Controls (Aux or Main)
Top Side Controls (Aux or Main)
Accessory connector
I/O connector
Pump 3
Pump 2
Pump 1
1 L
N
2 L
G
Heater communiaction
Circ. Pump (if required)
Ozone
12 volt Power Supply
Light connector
Top Side Controls (Aux or Main)
Top Side Controls (Aux or Main)
Accessory connector
I/O connector
Pump 3
Pump 2
Pump 1
Power connection for Heater
CINEMA SERIES SPAS
Non - CINEMA SERIES SPAS
Blower (if required)
XM Spa Packs
Speaker Lift (if required)
Power connection for Heater
1 L
N
2 L
G
(White Wire
To the Spa)
l i a t g i P e t i h W
White Pigtail
Neutral Bar
r a B l a r t u e N
a p S m o r F e t i h W
Spa
Wiring Requirements:
• 2-Hots, 1-Neutral, 1-Isolated Ground
• 0-40 length, 4 Wire #6 AWG copper conductor
Over 40 length, 4 Wire #4 AWG copper conductor
Note: The white neutral wire from the back of the GFCI MUST be
connected to an incoming line neutral. The internal mechanism of
the GFCI requires this neutral connection. The GFCI will not work
without it.
ATTENTION!
IMPROPER WIRING WILL VOID WARRANTY
To:
(Check your local Electrical codes for 60 Amp GFI circuits
for correct wire size for some areas varry)
1 L
N
2 L
G
3 L
1 L
N
2 L
G
3 L
1 L
N
2 L
G
3 L
When using three phase power
Pack settings should be:
Ph = 3
Br = 16 (amp)
Remove Jumper
When using two line power
connect First line to L1
and the second to L2 & L3
using Jumber with tab removed.
Pack settings should be:
Ph = 2
Br = 16 (amp)
When using single line
use jumper provided and connected
to L1, L2 & L3
Pack settings should be:
Ph = 1
Br = 32 (amp)
XM.ce 50 Hz Hook-up information
60 Hz 230 volts
16
NOTE!
NOTE!