Operating instructions

Swim Spa Operators Guide
(XM) CONFIGURATION
DESCRIPTION
Select button is used to access the phase conguration setting menu (short press) as
well as the low level programming menu (press and hold for 5 seconds). Subsequent
presses will save changes and display the next option available or exit automatically if
it was the last one.
Use change button to change the parameters displayed.
Press and hold select button for 5 seconds to activate low level programming. Once
activated, the display shows “LL” and, in succession, the current preset low level
conguration selected. (refer to page 20 for conguration number)
Press change button repeatedly to select the
the same preset low level conguration again.
Press select to conrm. You will exit menu automatically. The in.xm will then reset.
After resetting, the system starts a “learning sequence” in which each individual
output is activated and its peak current displayed and saved.
Note: This procedure has to be performed after every learning mode.
Note: If unusual current readings e.g.: 4 to 6 amps are detected on the high speed of any
pump, all pumps must be primed and the learning mode should be restarted.
SETTING THE LEARNING MODE
The in.xm pack has the ability to verify and “learn” the current consumption of every output
connected to it. If an output is replaced, a new learning must be done. Follow these simple steps:
+
L1
L2
N
G
+
L1
L2
N
G
+
L1
L2
N
G
+
L1
L2
N
G
+
L1
L2
N
G
+
L1
L2
N
G
NOTE!
NOTE!
19