Operating instructions

Swim Spa Operators Guide
01 - Not Used
02 - Not Used
03 - 2 Pump
04 - 2 Pump, Circ
05 - 2 Pump, Blower
06 - 2 Pump, Circ & Blower
07 - 3 Pump
08 - 3 Pump, Circ
09 - 3 Pump, Blower
10 - 3 Pump, Circ & Blower
11 - 3 Pump, Circ, TV & Speaker lifts
12 - Not used
13 - 3 Pump, Blower & Speaker Lift
14 - 3 Pump, Circ & Speaker Lift
(XM) CONFIGURATION
PROGRAMMING THE XM FOR DIFFERENT CONFIGURATIONS
Check water level, make sure all valves are open before switching on power.
Press and hold the select button for 5 sec. Or until “ll” ashes once.
Press the change button until the desired conguration number appears
(See chart below) press select to save changes.
The LED display will then ash “B2”. This is a current limit setting.
The most common setting is “32”. Press the change button until desired setting is displayed
(see current chart below.) Once more press select to save changes.
The pack will begin a test of all devices and measure the current
of each device. This information will be used by the pack to check
for problems and to limit the number of devices used at the same time.
This test will last about one minute depending on number of devices.
Once complete, the swim spa may be used as normal.
Programming the XM for Different configurations
01
02
03
04
05
06
07
08
09
10
11
12
13
14
- Not Used
- Not Used
- 2 Pump
- 2 Pump, Circ
- 2 Pump, Blower
- 2 Pump, Circ & Blower
- 3 Pump
- 3 Pump, Circ
- 3 Pump, Blower
- 3 Pump, Circ & Blower
- 3 Pump, Circ, TV & Speaker lifts
- Not used
- 3 Pump, Blower & Speaker Lift
- 3 Pump, Circ & Speaker Lift
88
Ok
+
Select Change
Check Water Level, make sure all Valves are open before switching ON power.
Press and hold the Select Button for 5 sec. or until
LL flashes once.
Press the Change button until the desired configuration number appears
(See chart below) press Select to save changes.
The LED display will then Flash “ ” this is a current limit setting.
most common setting is
32. press the Change button until desired
setting is displayed (See current chart below.) once more press Select
to save changes.
The Pack will begin a Test of all devices and measure the current
of each device. (this information will be used by the pack to check
for problems and to Limit the number of devices used at the same time.)
This Test will last about one min. depending on number of devices.
Once complete the Spa may be used as normal.
Located on the XM.CE pack
BR = 32 1 X 32 Amp GFCI Breaker
BR = 16 2 X 16 AMP GFCI Breaker
BR = 16 3 X 16 AMP GFCI Breaker
settting
Breaker installed in
power disconnect box
B2
B2
Located on the XM pack
BR = 32 1 X 32 Amp GFCI Breaker
BR = 16 2 X 16 AMP GFCI Breaker
BR = 16 3 X 16 AMP GFCI
Breaker installed in
power disconnect box
Breaker
settting
BR = 48 for 3 Pump
BR = 40 for 2 Pump
BR = 24 for 1 Pump
Breaker installed in
power disconnect box
Breaker
settting
Breaker Setting for CE Model
Breaker Setting for ETL Model
20