The high limit circuit is tripped. Usually, the kinetic heating protection or the current
monitoring circuitry will shut down the heater before the error can occur.
Add cold water to swim spa and let heater cool down. Reset swim spa pack using current
breaker.
Temperature probe defective.
This error clears itself when the error condition is no longer present. Reset the breaker if
the error is still there; replace the In.therm
The ID number of the in.therm vs the In.xm is wrong (CE/UL)
There is a CE In.Therm connected to a UL In.xm or vice versa. Change the In.Therm or
In.Xm to the appropriate version.
For all the above, the system has not detected a current change when turning on
or off the device.
Make sure the device is correctly connected and plug is sealed. If possible, manually
change the output status (on/off) of the device and cycle through all possible states (i.e
low and high speeds). Reset swim spa pack. If error does not clear, problem is probably
with the device and will need to be serviced.
This is not an error message
A solid Sc means the system is scanning all the output to learn the current draw of every
accessory connected.
A scan error was detected
Every time a low-level option is changed, the system must “learn” the currents associated
to each output/load. During this learning process, the device(s) connected to OUT8 (direct
output, no relay) must be disconnected (or off). If, not the system will report this code.
Once the load is correctly disconnected, the breaker has to be reset then the user needs
to restart the learning process by selecting the low level conguration and set the breaker.
Once the learning if nished, the accessories connected to OUT8 may be reconnected.
This is not an error message
The breaker size selected is lower than the total current of each output. The In.xm will
manage the current accordingly.