Operating instructions
Swim Spa Operator’s Guide
An Internal hardware error has been detected in in.xe.
• Restart the swim spa pack and start and stop all
pumps and blower.
• If error reappears, replace in.xe swim spa pack.
Water temperature at the heater has reached 119˚F.
DO NOT ENTER SWIM SPA WATER!!!
• Restart the swim spa pack.
• If error persists, measure the temperature with a digital
thermometer and compare. Its reading with temp. on the
display. Make sure the temp. reading is lower than 119˚F.
• If problem persists, replace pack.
Temperature inside the swim spa skirt is too high, causing the internal
temperature in the in.xe to increase above normal limits.
• Remove swim spa skirt and let system cool down, until the
error clears.
The system did not detect any water ow while the main pump was running.
• Make sure valves are open and that water level is
high enough.
• Check and remove anything obstructing the lter.
• Make sure there are no air locks or that no object
obstructs the passage of the water in the heater channel.
Pumps may make strange noises. Follow air lock
procedure to clear them.
The Prr error message indicates a problem with regulation probe. The system is
constantly verifying if temperature probe reading is within normal limits.
• Verify if regulation probe located above the heater is
properly connected.
• Replace in.xe heater is problem persists.
Water temperature in the swim spa has reached 108˚F.
DO NOT ENTER SWIM SPA WATER!!!
• Measure the temperature with a digital thermometer
and compare its reading with temp on the display. If temp
reading is different, replace heater.
• Remove swim spa cover and let swim spa cool down.
• Add cold water and lower lter cycles.
• If problem persists replace pack.
Applies to both
XE / S-CLASS
GENERAL XE PACK DISPLAY DIAGNOSTIC MESSAGE
36