Operating instructions

Swim Spa Operators Guide
CAUTION - RISK OF ELECTRIC SHOCK. Do not leave the CD
compartment open.
12)
WARNING - TO REDUCE THE RISK OF INJURY (CONT):
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
CAUTION - RISK OF ELECTRIC SHOCK. Replace components only
with identical components.
NOTE - The CD player controls are not to be operated while inside the swim spa.
WARNING - PREVENT ELECTROCUTION. Do not connect any
auxiliary components (for example, additional speaker, headphones, additional audio/video
components etc.) to the system. These units are not provided with an outdoor antenna.
Do not service this product yourself as opening or removing covers may expose you to
dangerous voltage or other hazards. Refer all servicing to your qualied swim spa tech.
If the power supply/supply cord(s) are damaged, if water is entering the speaker, CD
compartment, or any other component in the electrical equipment compartment area, the
protective shield is showing signs of deterioration, or there are signs of other potentially
hazardous damage to the unit, turn off the circuit breaker from the wall and contact or refer to
your service technician.
The unit should be subject to periodic routine maintenance once every quarter to make sure
that the unit is operating properly.
DANGER - RISK OF ELECTRIC SHOCK. Do not permit any electric
appliance, such as a light, telephone, radio or television within ve (5) feet of the swim spa.
A green colored terminal or a terminal marked G, GR. Ground, Grounding or the symbol shown
in Figure 14.1 of UL1563 is located inside the supply terminal box or compartment. To reduce
the risk of electric shock, this terminal must be connected to the grounding means provided in
the electric supply service panel with a continuous copper wire equivalent in size to the circuit
conductors supplying this equipment.
Do at least two lugs marked “Bonding Lugs” are provided on the external surface or on the
inside of the supply terminal box or compartment. To reduce the risk of electric shock, connect
the local common bonding grid in the area of the swim spa to these terminals with an insulated
or bare copper conductor not smaller than No. 6 AWG.
All eld-installed metal components such as rails, ladders, drains or other similar hardware with
3m of the swim spa shall be bonded to the equipment grounding bus with copper conductors
not smaller then No. 6 AWG.
13)
14)
15)
16)
17)
18)
8