Specifications
17
Infusion Device Analyzer
Optional accessories
9513-0212 External mini-keyboard, 
83-key with PS/2 connector and AT 
adapter
71072 Parallel Printer Cable  
(D25M-36M)
44277 PCA Trigger/Nurse Call Box
PRINTR/414-US120V Printer, Seiko 
DPU-414-30B (120 V power supply) 
(additional purchase required: parallel 
printer cable, p/n 71072)
PRINTR414-SHK220V Printer, Seiko 
DPU-414-30B (220 V power supply) 
(additional purchase required: parallel 
printer cable, p/n 71072)
61096 Printer (120 V power supply)
61097 Printer (220 V power supply)
3010-0441 Interface Cable, medTester 
to IDA 4 Plus (without wedge adapter) 
(RS-232; female DB25 to female DB9)
3010-0598 Interface Cable, medTester 
to IDA 4 Plus (with or without wedge 
adapter) (RS-232; female DB9 to female 
DB25)
9513-0221 Barcode Scanner (with 
long-reach coil cable with Y connector 
for keyboard attachment)
75029 Null Modem Cable (female DB9 
to female DB9)
Key features
• Tests up to four infusion pumps 
simultaneously
• Compatible with virtually any 
type of infusion device
• Instantaneous and average 
flow measurement
• Occlusion pressure measure-
ments to 45 psi
• Single- and dual-flow (piggy-
back) testing
• Full PCA testing (bolus volume, 
lockout time, and automated 
external triggering)
• Autostart mode enables unit to 
begin testing only when fluid is 
detected
• On-board graphing of pressure 
and flow
• Built-in memory to save test 
results for printing or down-
loading to computer
• Hydrograph graphical software 
to control unit and display 
results via PC
• Automated testing through 
Fluke Biomedical medTester 
5000C (US only)
• RS-232 ports
• Optional keyboard, printer, and 
alarm/PCA
IDA 4 Plus Multi-Channel Infusion 
Device Analyzer maximizes produc-
tivity with multiple, independent 
channels for testing upto four infusion 
pumps at once.
The device measures instantaneous 
flow, average flow, occlusion pressure, 
and analyzes patient-control analgesia 
(PCA) units. An optional PCA trigger 
box provides automated PCA pump con-
trol, allowing technicians to set 
up tests and walk away.
An autostart feature simplifies 
syringe pump testing or other tests that 
have long startup times.
With built-in memory, the IDA 4 Plus 
records test results internally and 
provides easy-to-read test-result 
graphs right on the analyzer’s screen. 
The display is so large numbers can be read from across the room
Additionally, the IDA 4 Plus comes with Hydrograph PC software for cre-
ating full-color graphs and reports. For automated testing, the IDA 4 Plus is 
compatible with Fluke Biomedical’s medTester 5000C (US only).
Flow-rate measurement
Technique Calculated by measuring a volume over time
Range 0.5 ml/hr to 1000 ml/hr
Accuracy 1 % of reading ± 1 LSD for flows of 16 ml/hr to 200 ml/hr for 
volumes over 20 ml; otherwise, 2 % of reading ± 1 LSD after 
delivery of 10 ml
Volume measurement
Technique Volume measured directly by the transducer in minimum 
sample sizes of 60 µl
Range 0.06 ml to 9999 ml
Accuracy 1 % of reading ± 1 LSD for flows of 16 ml/hr to 200 ml/hr for 
volumes over 20 ml; otherwise, 2 % of reading ± 1 LSD after 
delivery of 10 ml 
PCA bolus measurement
Technique Volume is measured directly by the transducer in minimum 
bolus volumes of 0.5 ml. The measurement is made with a 
continuous rate between 0 ml/hr and 30 ml/hr. The bolus flow 
rate should be at least four times the basal flow rate for reli-
able detection of boluses
Minimum bolus volume 0.5 ml
Accuracy See volume measurement
Pressure measurement
Technique Direct occlusion of the infusion line and measurement of pres-
sure prior to the glass transducer
Range 0 psi to 45 psi and equivalents in mmHg and kPa
Accuracy 1 % of full scale ± 1 LSD 
Back pressure -100 mmHg to 300 mmHg
IDA 4 Plus
Multi-Channel Infusion Device Analyzer
Specications