Specifications
25
Ordering information
ESA180-US 90-265V 180 Electrical 
Safety Analyzer
Included accessories
1751000 Users Manual
600/100FG Chassis Cable, 8 foot
Optional accessories
97148 Soft-sided Vinyl Carrying Case
600/100FG Chassis Cable, coil cord, 
8-foot extended
600/101FG Chassis Cable, coil cord, 
16 foot extended
600/200FG External Leakage Cable, 
coil cord, 8 foot extended
600/201 External Leakage Cable, coil 
cord, 16 foot extended
1800001 North American 220 V 
adapter kit
Key features
• Handheld
• Self-switching 120 V and  
240 V operation
• 15 A and 20 A capabilities
• Five patient applied parts jacks
• Dual-lead testing
The handheld 180 Electrical 
Safety Analyzer is a lightweight, 
portable device for testing elec-
trical systems, medical devices, 
and physiological instrumentation. 
The device includes the AAMI test 
load and has five jacks for patient 
applied parts testing.
Small enough to fit in a brief-
case, the analyzer works well as 
a bench-top instrument in the 
laboratory or a portable testing 
device in the mobile engineer’s 
toolbox. With its uncomplicated 
design, the 180 is simple to use.A single master function switch, directly 
labeled with the test to be performed, leads the user through a complete 
measurement procedure.
The analyzer uses simple, yet sophisticated, electronics for true-rms 
measurement of current and voltage. The 180 also performs dual-lead 
leakage and resistance tests.
Operating mains voltage range 90 V ac to 240 V ac
Current capacity for DUT Line 90 V to 140 V: 20 A for 5 min, 15 A for 30 min; line 
over 140 V: 10 A
Line-voltage measurement
Range 90 V to 240 V
Accuracy ± 3 % of reading ± 1 LSD
Load-Current measurement
Range 1 A to 19.99 A
Accuracy ± 5 % of reading ± 1 LSD
Leakage-current measurement
Range 0 µA to 1999 µA
Accuracy DC and 25 Hz to 1 kHz: ± 1 % of reading ± 1 µA; 1 kHz 
to 100 kHz: ± 2.5 % of reading ± 1 µA; 100 kHz to 1 
MHz: ± 5 % of reading ± 1 µA
Measurement type True-rms; input impedance per AAMI ES1-1993
Isolation test
Isolation source voltage 110 % of mains, ± 5 % of reading
Current limit 1 mA @ 120 V ac
Resistance measurement
Range
0.01 Ω to 19.99 Ω
Accuracy ± 1 % of reading ± 1 LSD
Resolution
0.01 Ω
Current source 10 mA dc
Environmental requirements
Operating temperature 15 °C to 40 °C (59 °F to 104 °F)
Storage temperature -20 °C to 65 °C (-4 °F to 149 °F)
Relative humidity 90 % max
Mains voltage range 90 V to 240 V
General information
Display LCD 3.5 digit
Dimensions (LxWxH) 13.3 cm x 18.4 cm x 5.4 cm (5.25 in x 7.25 in x 2.1 in)
Weight Max weight 1 kg (2.25 lb)
180
Electrical Safety Analyzer
Specications
Electrical Safety Analyzers