Specifications
27
Ordering information
LT544DLITE United States, 85 V ac to 
265 V ac, 50/60 Hz
LT544DLITE-EUR Europe, 85 V ac to 
265 V ac, 50/60 Hz
LT544DLITE-AUS Australia, 85 V ac to 
265 V ac, 50/60 Hz
LT544DLITE-ISR Israel, 85 V ac to  
265 V ac, 50/60 Hz
LT544DLITE-ITL Italy, 85 V ac to 265 V 
ac, 50/60 Hz
LT544DLITE-SWS Switzerland, 85 V ac 
to 265 V ac, 50/60 Hz
LT544DLITE-1520 United Kingdom,  
85 V ac to 265 V ac, 50/60 Hz ,15-Amp 
NEMA power plug with 20-Amp female 
power connector
LT544DLITE-2020 85 V ac to 265 V ac, 
50/60Hz, 20-Amp NEMA power plug 
with 20-Amp female power connector
LT544DLITE-230V 85 V ac to 265 V ac, 
50/60 Hz, with 230 V ac North America 
power plug and female power connector
Included accessories
600/100FG Chassis Cable, coil cord,  
8 ft extended
600/101FG Chassis Cable, coil cord,  
16 ft extended
600/102FG Chassis Ground Probe, 8 ft 
coil cord
600/600FG Soft Carrying Case (6 in x 
10 in x 4 in)
600/200FG External Leakage Cable, 
coil cord, 8 ft extended
600/201 External Leakage Cable, coil 
cord, 16 ft extended
600/206 Universal Ultrasound Probe 
Tester
Key features
• Small, lightweight, self-con-
tained portable instrument
• Universal power supply— 
input voltage from 85 V ac to 
265 V ac
• Chassis resistance mea-
surements are made with a 
four-wire Kelvin bridge to 
eliminate errors due to cable 
length
• Test method complies with 
AAMI load per ANSI/AAMI  
ES1-1993
• Leakage current can be mea-
sured in Open/Closed Neutral, 
Normal/Reversed Polarity and 
Open/Closed Ground
• All Leakage current measure-
ments are displayed directly  
in µA
This device is designed 
to perform simple 
electrical safety tests 
on any type of medical 
equipment, whenever 
patient lead testing is 
not required.
The rugged, hand-
held instrument is built 
for quick and easy use. 
A simple selector knob 
controls the functions: 
Leakage Current and 
Chassis Resistance. 
Accurate test measurements are shown on the large display.
Heavy-duty switches change polarity, open and close the neutral and 
select Chassis or Earth Leakage Current measurements. A four-wire Kelvin 
bridge eliminates reading errors in resistance due to cable length and 
contact resistance. True-rms measurements are provided for all current 
readings. The AAMI test load is utilized.
Ground resistance
Range
0 Ω  to 19.99 Ω
Accuracy ± 1% R, ± 1 LSD
Resolution
10 mΩ
Leakage current
Range 0 µA to 1, 999 µA
Accuracy DC and 25 Hz to 1kHz: ± 1 % of reading, ± 3 LSD 
1.0 KHz to 100 KHz: ± 2.5 % of reading, ± 3 LSD 
100 KHz to 1 MHz: ± 5 % of reading, ± 3 LSD
Current capacity
LT544DLite- 1515 15 A at 120 V ac
LT544DLite- 230 V 10 A at 230 V ac
LT544DLite- 1520/2020 20 A, at 230 V ac, 20 % duty cycle (2 minutes on, 8 minutes off)
Controls 1. Function switch – 4 position rotary 
2. Neutral switch – 2 position rocker (Open/Closed) 
3. Polarity switch – 3 position rocker (Normal/Off/Reversed) 
4. Leakage switch – 2 position rocker (Chassis/Earth)
DUT power 85 V ac to 265 V ac, 16 A @ 120 V, 10 A @ 230 V
Physical size 90 mm x 180 mm x 38 mm (3.5 in x 6.2 in x 1.6 in)
LT544DLITE
Digital Safety Tester
Specications
Electrical Safety Analyzers