Specifications
28
Ordering information
LT544DPLUS United States, 85 V ac to 
265 V ac, 50/60 Hz
LT544DPLUS-AUS Australia, 85 V ac to 
265 V ac, 50/60 Hz
LT544DPLUS-ISR Israel, 85 V ac to 265 
V ac, 50/60 Hz
LT544DPLUS-ITL Italy, 85 V ac to 265 
V ac, 50/60 Hz
LT544DPLUS-SWS Switzerland, 85 V ac 
to 265 V ac, 50/60 Hz
LT544DPLUS-UK United Kingdom, 85 V 
ac to 265 V ac, 50/60 Hz
LT544DPLUS-2020 85 V ac to 265 V 
ac, 50/60 Hz, 20-Amp NEMA power 
plug with 20-Amp female power 
connector
LT544DPLUS-230V 85 V ac to 265 V 
ac, 50/60 Hz, 230 V ac North America 
power plug and female power connector
Included accessories
600/100FG Chassis Cable, coil cord,  
8 ft extended
600/101FG Chassis Cable, coil cord,  
16 ft extended
600/102FG Chassis Ground Probe, 8 ft 
coil cord
600/600FG Soft Carrying Case (6 in x 
10 in x 4 in)
600/200FG External Leakage Cable, 
coil cord, 8 ft extended
600/201 External Leakage Cable, coil 
cord, 16 ft extended
600/206 Universal Ultrasound Probe 
Tester
Key features
• Small, lightweight, self-con-
tained portable instrument
• Universal power supply—input 
voltage from 85 V ac to  
265 V ac
• Chassis resistance mea-
surements are made with a 
four-wire Kelvin bridge to 
eliminate errors due to cable 
length
• Test method complies with 
AAMI load per ANSI/AAMI  
ES1-1993
• Leakage current can be mea-
sured in Open/Closed Neutral, 
Normal/Reversed Polarity and 
Open/Closed Ground
• All Leakage current measure-
ments are displayed directly  
in µA
This device is designed to 
perform simple electrical 
safety tests on any type 
of medical equipment, 
whenever patient lead 
testing is not required.
The rugged, hand-
held instrument is built 
for quick and easy use. 
A simple selector knob 
controls the functions: 
Line Voltage, Instrument 
Current, Leakage Current 
and Chassis Resistance. 
Accurate test measurements are shown on the large display.
Heavy-duty switches change polarity, open and close the neutral and 
select Chassis or Earth Leakage Current measurements. A four-wire Kelvin 
bridge eliminates reading errors in resistance due to cable length and 
contact resistance. True-rms measurements are provided for all current 
readings. The AAMI test load is utilized.
Line voltage
Range 85 V ac 265 V ac
Resolution 1 Volt
Accuracy 2 % R ± 1 LSD
Instrument current
Range 0.0 A to 19.99 A
Resolution 10 mA
Accuracy 5 % R ± 1 LSD
Ground resistance
Range 0 W 19.99 W
Accuracy ± 1 % R, ± 1 LSD
Resolution 10 mW
Load current
Range 0 A to 14.99 A (LT544Dplus – 1515) 
0 A to 19.99 A (LT544Dplus – 2020)
0 A to 9.99 A (LT544Dplus – 230 V)
Accuracy ± 4 % R, ± 1 LSD
Leakage current
Range 0 µA to 1, 999 µA
Accuracy DC and 25 Hz to 1 kHz: ± 1 % g, ± 3 LSD
1.0 KHz to 100 KHz: ± 2.5 % of reading, ± 3 LSD
100 KHz to 1 MHz: ± 5 % of reading, ± 3 LSD
Current capacity LT544Dplus-1515: 15 A at 120 V ac
LT544Dplus-230V: 10 A at 230 V ac 
LT544Dplus-2020: 20 A, at 120 V ac, 20 % duty cycle  
(2 minutes on, 8 minutes off)
Controls 1. Function Switch - 4 position rotary 
2. Neutral Switch - 2 position rocker (Open/Closed) 
3. Polarity Switch - 3 position rocker(Normal/Off/Reversed) 
4. Leakage Switch - 2 position rocker (Chassis/Earth)
DUT power 85 V ac to 265 V ac, 16 A @ 120 V, 10 A @ 230 V
Power connectors LT544Dplus – Standard US 
LT544Dplus-EUR – Schuko
Physical size 90 mm x 180 mm x 38 mm (3.5 in x 6.2 in x 1.6 in)
LT544DPLUS
Digital Safety Tester
Specications
Electrical Safety Analyzers