Specifications
5
The Impulse 6000D Defibrillator Analyzer and Impulse 7000DP 
Defibrillator/Transcutaneous Pacemaker Analyzer Test Systems are rugged, 
portable precision test instruments that ensure proper operation and ulti-
mate performance of critical life-support cardiac-resuscitation equipment. 
The Impulse 6000D and Impulse 7000DP test capabilities encompass the 
spectrum of worldwide-established pulse shapes, showcase breakthrough 
AED technology compatibility, and outperform in accuracy and standards. 
Additionally, the Impulse 7000DP incorporates the tests and the extensive 
range of test loads and measurement algorithms needed to test external 
transcutaneous pacemakers.
In conjuntion with an Impulse 7000DP, the Impulse 7010 Defibrillator 
Selectable Load Accessory provides multiple loads of 25 Ω, 50 Ω, 75 Ω, 
100 Ω, 125 Ω, 150 Ω, 175 Ω, and 200 Ω for defibrillator performance 
testing. A standard USB interface enables computer control and data 
transfer, and optional Ansur PC-based automation software increases pro-
ductivity by outfitting users with an easy-to-use method to standardize 
testing procedures and capture, print and document data.
Model QED 6 Impulse 6000D Impulse 7000DP
Monophasic and dc 
biphasic energy capability
Yes Yes Yes
Pulsed biphasic engery 
capability
No Yes Yes
Defibrillator tests Output energy Output energy Output energy
Cardioversion Cardioversion Cardioversion
Peak measurements Max energy/ 
charge-time overshoot
Max energy/ 
charge-time overshoot
— Peak and average 
current
Peak and average 
current
— Voltage measurement Voltage measurement
Normal ECG/performance 
waves
No Yes Yes
Transcutaneous pacer tests No No Yes
Key features
• Impulse 7010 Defibrillator 
Selectable Load Accessory 
provides multiple loads of 25 Ω, 
50 Ω, 75 Ω, 100 Ω, 125 Ω,  
150 Ω, 175 Ω, and 200 Ω to 
comply with IEC 60601-2-4 
standard (optional)
• Lown, Edmark, trapezoidal, 
biphasic and pulsed bipha-
sic defibrillation technology 
compatibility
• AED technology compatibility
• First-class measurement 
accuracy: ± 1 % of reading  
0.1 J
• Intuitive user interface and 
backlight, easy-to-ready 
display
• Portable, rugged, easy to carry
• Long-lasting, rechargeable 
battery
• Internal pacer brand selections
• Pacer input protected against 
defibrillator output (7000DP 
only)
• 10 isolated ECG electrodes that 
provide 12 combinations for 
standardized clinical signals
• Flexible heart-rate settings 
(1 BPM step) facilitate rate 
meter accuracy and alarm 
testing
• DSP-based measurements 
enable future firmware and 
waveforms upgrade
• Unique integrated posts for 
secure connections 
• Optional Ansur test automation 
software to standardize testing 
procedures, capture waveforms, 
and print and document test 
result
Impulse 6000D/7000DP
Debrillator/Transcutaneous Pacemaker Analyzer
Product comparison chart
Defibrillator/Transcutaneous Pacer Analyzers
Note: AC pulsed biphasic waveform has not been approved in the United States.