Specifications
Troubleshooting and Technical Information
24 Dynaudio SUB 300/500
Technical specifications
All aspects relating to the performance criteria are strictly controlled. Along all stages
of the entire production progress – from raw material selection to the final assembly
and quality control – Dynaudio thoroughly inspects each parameter along every step
of way.
Subject to alterations.
SUB 500 SUB 300
Frequency response
(± 3 dB)
18 Hz - 250 Hz 25 Hz - 250 Hz
Low frequency limit with
EXT Off
27 Hz 33 Hz
Amplifier power 250 W / 4 Ohm 200 W / 4 Ohm
Cross-over frequencies 60 Hz / 80 Hz / 100 Hz 60 Hz / 80 Hz / 100 Hz
Cross-over slope 4th order, Linkwitz-Riley 4th order, Linkwitz-Riley
Cross-over bypass Yes (FLAT) Yes (FLAT)
Phase adjustment 0° / 90° / 180° / 270° 0° / 90° / 180° / 270°
Inputs Single ended/RCA,
Balanced/XLR
Single ended/RCA,
Balanced/XLR
Input sensitivity for full output* 0.1 V - 5 V 0.1 V - 5 V
Maximum input 10 V 10 V
Input impedance 20 kOhm 20 kOhm
Output Single ended/RCA,
Balanced/XLR
Single ended/RCA,
Balanced/XLR
Master/Slave link Yes Yes
Remote control included included
No. of presets 4 4
Each preset includes level, cross-over frequency,
phase, ext. frequency range
level, cross-over frequency,
phase, ext. frequency range
Drive unit 12" (30 cm), long throw 10" (24 cm), long throw
Magnetic shielding Yes Yes
Internal cabinet volume 36 litres 19 litres
Bass principle Closed Ported
Power consumption, max. 480 W 480 W
Power consumption, standby 5 W 5 W
Mains voltage** 120 V/60 Hz or 230 V/50 Hz 120 V/60 Hz or 230 V/50 Hz
Weight (net) 30.6 kg 19.1 kg
Dimensions (W x H x D) 360 x 378 x 568 mm 320 x 338 x 466 mm
* Depended on setting.
** Please refer to your local network.