POWER REQUIREMENTS
Power Requirements and Installation—North America, Japan, and Locations Using 60 Hz Power
Version 1 Control Panel Interface Installation and User Guide
D-3
TESTING FOR CORRECT VOLTAGES
You must test the receptacle for proper voltages before the dyno is connected to the
outlet.
If the voltage readings do not match the following table, DO NOT connect the
dyno. You must have a licensed electrician correct the power connection.
Connecting the dyno to the incorrect voltage can result in damage to the dyno
and will void the dyno warranty. Contact Dynojet with any questions.
Using a voltmeter that is capable of measuring AC voltage, measure between the
points listed below and verify that the correct voltages are present.
Figure D-1: Dedicated Power Receptacle
probe 1 probe 2 desired voltage measurement
2 4 225V to 250V
1 4 108V to 130V
1 2 108V to 130V
13 <5V
3box<5V
4
1
2
3