INSTALLATION GUIDE
Installation
Version 2 Power Carriage Installation Guide
5
2 Slide the motor mount assembly and flange bearing, removed earlier, over the
screw shaft. Make sure the flex coupling is on the shaft.
Note: The flange bearing must be facing as shown in Figure 4 so the grease zerk is
accessible.
3 Secure the motor mount assembly and flange bearing to the carriage using two
1/4 x 1-inch bolts and lock washers.
Note: Dynojet recommends using a 1/4-inch ratchet drive with universal joint and
a 7/16-inch shallow socket to secure the flange bearing bolts.
4 Using a 1/8-inch allen wrench, tighten the flex coupling set screw.
Figure 4: Install the Motor Mount Assembly
motor mount
assembly
screw shaft
flex coupling set screw
flange bearing bolts
grease zerk
flex coupling
flange bearing