Motorcycle Accessories User Manual
Torque Module Installation and User Guide for Model 250 Dynamometers
CHAPTER 1
Load Cell Installation
1-6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOAD CELL INSTALLATION
This section describes how to remove the hood, install the load cell, and replace the
hood.
REMOVING THE HOOD
1 Disconnect all power to the dyno.
2 Remove the four bolts securing the eddy current brake cover and set aside.
Note: You may want to place the four bolts you just removed back into the hood
to prevent misplacement.
3 Remove the two bolts securing the hood clamps to the brake and set aside.
Figure 1-4: Remove the Brake Cover and Hood Clamps
4 Remove the four bolts securing the hood to the dyno and prop up the hood.
5 Disconnect the wires to the key switch if present.
6 Disconnect all battery wires.
7 Remove the hood from the dyno and set aside.
Figure 1-5: Remove the Hood
brake cover
hood clamps
key switch