Manual

Torque Module Installation and User Guide for Model 250 Dynamometers
CHAPTER 2
Torque Cell Calibration
2-6
While installing the calibration weights, you should notice the Torque Gauge on the
DynoTrac Window moving from 0 to about 500 foot-pounds.
Note: The Torque Gauge may or may not be in this range. If the torque cell has
been previously calibrated incorrectly or has not been calibrated for a while, the
gauge may show values out of this range until calibration is complete.
Note: Let the torque gauge needle stabilize before clicking Next.
9From the Span Calibration window (Figure 2-4), click Next to continue.
Note: At this point, the value on the gauge should match the value on the
calibration arm.
10 Remove the calibration arm and weights and click Finish.
Figure 2-6: Calibration Is Complete Window