User Manual

DYNO PRE-INSTALLATION INFORMATION
Specifications and Requirements
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
5
DRILL AND DRILL BIT REQUIREMENTS
You will need to provide a drill and drill bit capable of drilling holes in concrete. Refer
to Appendix A for more information on installing Red Head Anchors.
drill bit size: 1/2-inch
minimum hole depth: 1 5/8-inch (41.2 mm)
ELECTRICAL REQUIREMENTS
The dynamometer requires a dedicated electrical circuit for reliable and precise
operation. No other loads should be plugged into this circuit and this circuit should
be independent of the lighting in the room.
Note: You will need to provide an additional circuit for the computer and dyno
electronics.
description specifications
Power Requirements 240v 30amp single phase circuit
Refer to Appendix B for power requirements and
installation.
Frequency 50 or 60 Hz
Voltage
normal 240 VAC
min./max 215 VAC/245 VAC except Japan 195 VAC/245 VAC
Current 30amps
Power Consumption 7200 watts
Power Cord P/N 76950401
length 3.048 m (10.00 ft.)
end twist-lock plug or three-pin IEC plug
wall receptacle (included with dyno) twist-lock four wire grounded 30A NEMA L14-30 or
three-pin IEC grounded 30A
Full Load Amperage (FLA) 30A