Installation Guide User Manual

Linx Installation for Model 424 Automotive Dynamometers
424 LINX INSTALLATION
Pulley Mounting Plates and Outer Bearings Installation
26
INSTALLING THE STATIONARY DYNO PULLEY OUTER BEARING, BEARING MOUNTING PLATE,
AND LOWER PULLEY MOUNT
1 Secure the outer stationary dyno pulley bearing to the stationary dyno pulley
bearing plate using four 9/16-12 x 2-inch bolts, four 9/16-inch flat washers, and
four 9-16-inch nuts. Slide this assembly onto the stationary dyno pulley outer
shaft.
Figure 23: Install the Outer Stationary Dyno Pulley Bearing and Bearing Plate
2 Place a lower stationary dyno pulley mount (P/N 61300023) under the stationary
dyno pulley and loosely secure the mount to the inner plate using
five 3/8-16 x 1-inch bolts and five 3/8-inch flat washers (one of the holes on the
pulley mount is not used).
3 Loosely secure the pulley mount to the stationary dyno pulley bearing plate using
five 3/8-16 x 1-inch bolts and five 3/8-inch flat washers.
Figure 24: Secure the Pulley Mount Under the Stationary Dyno Pulley
XD061
stationary dyno
pulley bearing
stationary dyno
pulley bearing plate
stationary dyno
pulley
XD062
pulley mount
P/N61300023
stationary dyno
pulley bearing plate