Installation Guide Owner manual
3-27
4WD DYNO INSTALLATION
Hydraulic Movement Installation
Version 1 Above Ground Model 424x/424xLC
2
Automotive Dynamometer Installation Guide
ROTATING THE HYDRAULIC MOTOR
Before rotating the hydraulic motor, verify the motor is wired for your needs. The
motor is wired for 110v but can be changed to 220v. Refer to “Wiring the Hydraulic
Motor” on page 3-29.
1 Remove the four bolts and washers securing the motor.
Figure 3-16: Removing the Hydraulic Motor
AD486
motor
wiring box cover