Owner manual

Proportional Air Brake Installation Guide
PROPORTIONAL AIR BRAKE
Installation
6
5 Attach the air line labeled OUT from the EPR to the three-way valve on the prop
air regulator assembly. Push the hose in and hand tighten the fitting.
6 Attach the air line labeled IN from the EPR to the brass four-way fitting on the
prop air regulator assembly.
Note: Pull on both hoses to ensure they are secure. If there is movement, tighten
the fitting.
7 Connect your shop air to the dyno.
Dynojet recommends using an air filter/dryer. Failure to use clean, dry air will
compromise the integrity and life of the air components.
7a Mount the air pressure regulator on the wall in your shop with the bracket
provided.
7b Connect a supply air hose to the inlet of the regulator from your shop air
supply and a 3/8-inch air hose to the outlet side. The regulator should be set
to 60 psi.
7c Connect the 3/8-inch air hose coming from the air pressure regulator to the
barbed inlet fitting on the prop air regulator assembly.
Note: Make sure the arrow on the regulator is the same as the direction of the air
flow.
Figure 5: Routing Cables—Air Lines
EPR air line in
attaches to brass
four-way fitting
EPR air line out
attaches to
three-way valve
regulated air
out
in