Installation Guide Owner manual
EMS Configuration     
Exhaust Gas Temperature (EGT) 
Select the alarm mode and the analog bar thresholds as 
described in Alarm and Color Threshold Configuration on 
page 5-2. If one or more EGT thermocouples have been 
insta
lled, set the DISPLAY parameter to ON; if no EGT 
thermocouples are installed, set it to OFF. There is no need 
to set a sensor type; any K-type thermocouple will work for 
this input. 
In addition to the configuration of the color thresholds, you 
can configure the top and bottom of the EGT/CHT analog 
scales independently. This allows you to show a narrower 
region of interest on the analog gauges to ensure easy detection of minor differences between 
cylinders. The TOP OF SCALE parameter defines the highest temperature displayed on the EGT 
analog gauge; The BOT OF SCALE parameter defines the lowest temperature displayed on the 
EGT analog gauge; the SCALE SECTIONS defines the number of sections into which the entire 
scale range is divided. Set the TOP OF SCALE, BOT OF SCALE, and SCALE SECTIONS to 
suit your needs. 
For all SPLIT cylinder displays (2 cylinders only), you can set the SCALE SECTIONS for EGT 
and CHT independent of each other. For COMBD displays, EGT and CHT SCALE SECTIONS 
are tied together as the two sets of measurements are displayed on the same graph. 
SPAN ALARMS 
You may configure alarms based on the overall temperature 
span between the hottest and coolest cylinders’ EGTs. The 
span alarm configuration is located on the second page; 
press DOWN▼ from the bottom of page 1. First, press 
SEL► to toggle the DETECT setting to ON. Like other 
alarms, you can cycle ALARM through SELF-CLEAR, 
LATCHING, and OFF. See Alarm and Color Threshold 
Configuration on page 5-2 for definitions of those 
functions. Next, configure the MAX SPAN (the maximum 
temperature difference between hottest and coolest 
cylinders, in the units shown at the top of the menu) during non-leaning conditions. Next, 
configure the maximum span while leaning in the WHEN LEANING section. If you do not wish 
to have a different span alarm value while leaning, you must still configure this value to equal 
that of MAX SPAN. When the difference between your hottest and coldest cylinders’ EGTs is 
greater than the MAX SPAN value (or WHEN LEANING value, when leaning), a span alarm is 
triggered. When this occurs, those two EGT values will alternate between their actual value and 
a SPN alert. If you have configured the ALARM setting to either SELF-CLEAR or LATCHING, 
the SPN alarm will be red and will be accompanied by an alarm bar. If you have configured 
ALARM to be OFF, the SPN alarm will be yellow. 
5-10 EMS-D10 Installation Guide 