Installation Guide Owner manual
EMS Configuration     
General Purpose Thermocouple 
Select the alarm mode as described in the Alarm and 
Color Threshold Configuration section on page 5-2. 
Configure the GP therm
ocouple info bar to display in the 
desired location(s), as described in the EMS-D10 Pilot’s 
User Guide > Global Configuration Settings > Info Item 
Configuration
 section. 
After configuring alarms, press DOWN▼ to select the LABEL 1 field. The first character of the 
4-character name is highlighted. Press INC+ or DEC- to cycle through the numbers and letters 
for the first character. When you have selected the desired letter, press SEL► to move to the 
next character. Repeat this for each of the characters in the contact name field. If desired, repeat 
this for LABEL 2. If you leave LABEL 2 with its default “----” value, the temperature units are 
displayed beneath the temperature bar’s label; otherwise, the value of LABEL 2 is displayed. Set 
the SENSOR TYPE to J or K, depending on the thermocouple type used. 
Sensor 
Type 
GP Temp Sensor 
J  J Type Thermocouple 
K  K Type Thermocouple 
5-20 EMS-D10 Installation Guide 