Installation Guide Instruction Manual
9. APPENDIX 
The appendices contain additional information pertaining to the installation of the FlightDEK-
D180. You will find here a table of weights, specifications, the maintenance manual, the OAT 
Installation and Operating Guide, the AOA Pitot Installation Guide, and the Blind encoder 
Serial-to-Gray Code Installation Guide. 
Appendix A: Ongoing Maintenance and Troubleshooting 
INTRODUCTION 
This section gives the installer or mechanic information pertaining to maintenance of the 
FlightDEK-D180. Additionally, it provides the steps necessary to ensure continued airworthiness 
for the unit. 
CAUTION 
With the exception of replacing the internal emergency battery, the FlightDEK-D180 contains no 
user-serviceable parts. Refer all servicing to Dynon Avionics. 
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS 
Other than for regulatory periodic checks and an annual internal battery capacity test (if optional 
internal emergency battery is installed), maintenance of the FlightDEK-D180 is “on-condition” 
only. With the exception of the battery, periodic maintenance of the FlightDEK-D180 is not 
required. 
AP SERVO INSTALLATION 
At least once per year, inspect the installation of the AP servo(s) for excessive wear. Ensure that 
all hardware and fasteners are tightly secured. 
ALTIMETER CHECK 
The following test can be performed on an as-needed basis. If the altimeter is found to be out of 
specification, the following single-point adjustment can be performed by navigating the menus to 
SETUP > ALTADJ. In the Altimeter Adjustment menu, you can change the displayed altitude by 
up to 500 feet up or down. After making this adjustment, ensure that the altimeter on the 
FlightDEK-D180 meets the tolerances allowed between 0 and 30,000 feet. If this adjustment 
does not bring the altimeter on the FlightDEK-D180 to within specification at all attitudes, 
please contact Dynon Avionics to return for service. 
INTERNAL BATTERY CHECK 
If your FlightDEK-D180 has a rechargeable internal emergency battery, it is necessary to ensure 
that the battery capacity is such that it will last at least 1.5 hours on a full charge. At least once 
per year, perform the following test. 
1.
  With the FlightDEK-D180 drawing power from an external source, allow it to charge its 
internal battery above 16.0 volts. Observe the voltmeter under the INFO selection option 
FlightDEK-D180 Installation Guide 
9-1 