Installation Guide Instruction Manual
 Appendix 
FlightDEK-D180 Installation Guide    9-3 
DISPLAYED ALERT MESSAGES 
The following table describes the alert messages that the FlightDEK-D180 can display. 
Alert Message  Description  End condition 
INTERNAL 
ERROR 
SERVICE UNIT 
This error can occur for a few 
reasons, including an aborted upload. 
It signifies that the FlightDEK-D180 
has detected internal problems in its 
firmware or calibration tables. 
When this error appears, it may be 
possible to recover your unit in the 
field. The best way of ensuring this 
is to call Dynon Avionics 
immediately. However, there is a 
good possibility that the unit will 
have to be returned for service. 
ATTITUDE 
RECOVERING… 
This alert is displayed anytime the 
unit is rotated at a rate faster than 
150 degrees/second or the unit is 
powered on with airspeed applied. 
Rotating the unit faster than this 
threshold will saturate the gyros, 
leading to potentially erroneous 
display. The blue/brown horizon 
indication will turn grey and black to 
indicate that the artificial horizon is 
not currently a trusted source. Note 
that this alert only appears when 
airspeed is non-zero; using the 
FlightDEK-D180 on the bench will 
not trigger this alert. 
The grey/black horizon indication 
and onscreen message will remain 
until the unit has resumed normal 
operation. In the case of rotation 
rate greater than 150 
degrees/second, the unit enters a fast 
recovery mode and usually recovers 
within 5 seconds of coordinated 
flight. 
TEMPERATURE 
UNSTABLE 
When the unit is turned on after 
having been off for a long period, its 
internal temperature will rise above 
ambient at a fast rate. This fast 
change in temperature can sometimes 
reduce the reliability of the output of 
the sensors. Therefore, this alert is 
displayed and the horizon indication 
is changed from blue/brown to 
grey/black. 
The screen remains normal color, 
but the message is displayed until 
the temperature within the unit has 
stabilized. This temperature 
instability should last no longer than 
2 minutes. For this reason, it is a 
good idea to turn the unit on before 
you run through any of the preflight 
procedures, so that it will be ready 
by the time you are ready to fly. 
TEMPERATURE 
OUT OF SPEC 
The temperature inside the unit is 
outside of -30ºC to 50ºC. 
The screen remains normal color, 
but the message is displayed until 
the temperature within the unit is 
within the specified range. This is 
most common in unventilated 
panels during hot periods. If you 
continue to see this alert, provide 
more airflow to the space around the 
FlightDEK-D180. 