Instrument Installation     
Connecting Static & Pitot Lines 
4-14    FlightDEK-D180 Installation Guide 
The AOA, pitot, and static ports on the back of the 
FlightDEK-D180 are equipped with 1/8” NPT 
Female fittings. To attach your pitot and static lines 
to the back of the FlightDEK-D180, you must use 
standard 1/8” NPT Male fittings at the end of each 
of the lines. 
The FlightDEK-D180’s attitude 
calculation requires either airspeed 
(from pitot and static) or GPS data. 
To ensure proper operation, at least 
one of these data sources must be 
available. We recommend the 
FlightDEK-D180 be connected to 
pitot and static systems in all 
installations. 
To install, simply connect your static and pitot 
sources to the FlightDEK-D180, T’ing off of 
existing lines if performing a retrofit. View the 
following back view diagram the placement of your 
pressure lines. 
Use a wrench to secure the mating pressure line fittings to the corresponding locations on the 
back of the FlightDEK-D180. Do not over-tighten. 
If you purchased Dynon’s AOA pitot tube, note that it has pitot and AOA ports on it, but not 
static. You will need to provide your own source of static pressure for the FlightDEK-D180 and 