 EMS Configuration 
Voltage 
The voltmeter info item reports the voltage that the FlightDEK-D180 reads on its Master Power 
input (pin 1 on the EFIS 25-pin connector). Because of this, there is no sensor to install or 
configure. Simply, select the alarm mode and the analog bar thresholds as described in Alarm 
and Color T
hreshold Configuration on page 6-2. Configure the voltmeter inf
o bar to display in 
the desired location(s), as described in the FlightDEK-D180 Pilot’s User Guide > Global 
Configuration Settings > Info Item Configuration
 section. 
Current 
If a current sensor has been installed, set the DISPLAY 
parameter to ON, otherwise, set it to OFF. First, select 
whether your ammeter will be showing positive and 
negative currents (-60A TO 60A; used for Location A) 
or only positive currents (0A TO 60A; used for 
Locations B and C). This will depend on your 
installation as mentioned in the Ammeter 
Shunt installation section on page 3-12. Select 
the alarm
 mode and the analog bar thresholds 
as described in Alarm and Color Threshold 
Configuration on page 6-2. Change the 
SENSOR TYPE to the correct num
ber using 
the sensor type table. Configure the ammeter 
info bar to display in the desired location(s), 
as described in the FlightDEK-D180 Pilot’s 
User Guide > Global Configuration Settings > 
Info Item Configuration
 section. 
Sensor 
Type 
Ammeter Sensor 
1 Dynon P/N 100412-000 
2 GRT CS-01 
If you are using the GRT CS-01 Hall effect sensor, you m
ay need to set the zero-point of the 
sensor. After you have selected a SENSOR TYPE of “2,” the OFFSET parameter will be 
displayed. Adjust the OFFSET (in increments of 1 amp) until the current displayed on the EMS 
Main page screen is correct at a known current. 
FlightDEK-D180 Installation Guide    6-15 