Installation Guide Instruction Manual
EMS Configuration     
General Purpose Inputs 
In each of the 3 EMS GP INPUT submenus, 
you must select the function corresponding to 
the sensor that is installed for the respective 
GP connection. Ensure that you have 
configured your info items on the main and 
aux pages to display the desired GP inputs. 
Note that each GP menu will have help text, 
reading “DISPLAYED: INFO #” for each 
info item position where the given GP 
parameter is displayed. If the given info item 
is not configured to display anywhere, no text 
will be shown. Configure the info item (bar, text, or flaps/trim) for each GP input to display in 
the desired location(s)s, as described in the FlightDEK-D180 Pilot’s User Guide > Global 
Configuration Settings > Info Item Configuration
 section. 
  The General Purpose Inputs listed below the HS34 INPUTS section, (HS34 GP INPUT 1, 
2, 3) can only be used with an HS34 installed and configured 
  We recommend that you set the FUNCT for all unused GP inputs to UNUSED. 
ROTAX CHT 
Select GP INPUT 1 and press SEL► to change the FUNCT parameter to ROTAX CHT L. Back 
out and select GP INPUT 2 and press SEL► to change the FUNCT parameter to ROTAX CHT 
R. Refer to the Cylinder Head Temperature (CHT) setup section on page 6-11 for information 
about changing the various CHT-related param
eters. 
RESISTIVE FUEL LEVEL 
Under the desired GP input number, set FUNCT to FUEL LVL 3 or FUEL LVL 4 (if FUEL 
LVL 3 has already been chosen on a different GP input). All fuel level inputs use the same alarm 
settings. Configure these as described in the Alarm and Color Threshold Configuration section 
on page 6-2. 
CARBURETOR TEMPERATURE 
Sensor 
Type 
Carburetor Temp Sensor 
1 
Dynon P/N 100413-000 
(with black wires) 
2 GRT CARB-01 
3 
Dynon P/N 100468-000 
(with white/black wires) 
Under the desired GP input number, set FUNCT to 
CARB TEMP. Select the analog bar thresholds as 
described in the Alarm and Color Threshold 
Configuration section on page 6-2. Set the 
SENSOR TYPE to the correct num
ber using the 
sensor type table. 
6-16    FlightDEK-D180 Installation Guide 