Installation Guide Instruction Manual
 EMS Configuration 
COOLANT TEMPERATURE 
Sensor 
Type 
Coolant Temp 
Sensor 
1 Dynon P/N 100409-001 
2 
Chevrolet LS7 pre-
installed 
3 Dynon P/N 100409-000 
4 Rotax 801-10-1 
Sensor 
Type 
Coolant Pressure 
Sensor 
1 Dynon P/N 100411-000 
Sensor 
Type 
OAT Sensor 
1 
Dynon P/N 100433-000 
(2-wire) 
Dynon P/N 100433-001 
(3-wire, when installed 
as described on page 3-
13) 
2 GRT OAT-01 
Under the desired GP input number, set FUNCT to 
COOL TEMP. Select the analog bar thresholds as 
described in the Alarm and Color Threshold 
Configuration section on page 6-2. Set the SENSOR 
TYPE to the correct number using the sensor type table. 
COOLANT PRESSURE 
Under the desired GP input number, set FUNCT to 
COOL TEMP. Select the analog bar thresholds as 
described in the Alarm and Color Threshold 
Configuration section on page 6-2. Set the SENSOR 
TYPE to the correct number using the sensor type table. 
OUTSIDE AIR TEMPERATURE SENSOR 
Under the desired GP input number, set FUNCT to 
OAT. Select the analog bar thresholds as described in 
the Alarm and Color Threshold Configuration section on 
page 6-2. Set the SENSOR TYPE to the correct number 
using the sensor type table. 
If you have installed a D
ynon Avionics OAT to a 
General Purpose Input enter the EMS setup menu by 
pressing SETUP > SENSOR > EMS GP INPUT. Set the 
desired GP Input to OAT and select sensor type 1. 
  If the OAT is connected to the EMS D37 
connector, do not set the sensor type in the EFIS > SETUP > OAT menu. Ensure that the 
INSTALLED value in the EFIS OAT menu is set to N. 
AILERON TRIM 
Under the desired GP input number, set FUNCT to TRIM AILRN. There are no alarm thresholds 
or any other setting required for aileron trim. 
ELEVATOR TRIM 
Under the desired GP input number, set FUNCT to TRIM ELEV. There are no alarm thresholds 
or any other setting required for elevator trim. 
RUDDER TRIM 
Under the desired GP input number, set FUNCT to TRIM RUDR. There are no alarm thresholds 
or any other setting required for rudder trim. 
FLAP POSITION 
Under the desired GP input number, set FUNCT to FLAP POS. There are no alarm thresholds or 
any other setting required for flap position. 
FlightDEK-D180 Installation Guide    6-17 