Installation Guide Instruction Manual
2. WIRING OVERVIEW 
Please follow these instructions explicitly as improper wiring can result in permanent damage to 
your instrument and/or the accompanying sensors. 
All electrical power and EFIS-specific lines interface with the FlightDEK-D180 via the female 
25-pin D-sub connector on the back of the instrument. All EMS-related sensor inputs enter the 
FlightDEK-D180 via the male 37-pin and female 25-pin D-sub connectors on the back of the 
instrument. Ensure that the unit powers on and that all indicators display expected values before 
completing the final physical assembly. 
Recommended Wiring Practices 
  For all electrical connections, use correct wiring techniques, taking care to properly 
insulate any exposed wire. A short circuit between any of the wires may cause damage to 
the FlightDEK-D180 and/or your aircraft. Make all connections to your harness before 
plugging it into any of the components of the system. Do not make connections while 
power is applied at any point in the system. 
Dynon Avionics sells wiring harnesses for all connections to the FlightDEK-D180. The 
harnesses are made up of 22 AWG wire and – with the exception of the thermocouple harnesses 
– meet Mil Standard MIL-W-22759/16 (Tefzel insulation). If you have opted not to purchase 
these harnesses, please refer to the provided wiring diagrams for construction information. We 
recommend that all wire you use also meets Mil Standard MIL-W-22759/16; all wire supplied by 
Dynon Avionics (with the exception of thermocouple wire, which uses FEP insulation) meets 
this specification. 
When using any pre-manufactured harness, verify that each pin has continuity with the expected 
wire on the wiring diagram. This test can be easily done with a multimeter. When verifying 
harnesses, use the wiring charts and diagrams in this guide as your ultimate authority on pin 
function (for any harness) and wire color (for harnesses purchased from Dynon Avionics). 
Route all wiring through the engine compartment such that there are no spots where it could 
chafe or break. Use appropriate strain relief at all junctions between wires and connectors. We 
recommend that you secure all wires at regular intervals along wiring runs to accommodate 
vibration effects. 
In the sections below, many connections have an 
associated legend, as shown at right. All connections on 
the EMS male 25-pin harness route to thermocouples and 
are color-coded to correspond to the thermocouple 
coloring. All connections on the EFIS female 25-pin harness are described in the 25-Pin Female 
EFIS Harness section on page 2-4. 
Pin  Color  Function 
# Color  function 
Power Requirements 
22 AWG wire is normally sufficient for the power supply and ground lines, but we recommend 
that you consult a wire sizing chart and determine the size required for the wire routing in your 
particular aircraft. Ensure that the power lines include a circuit breaker or an appropriately sized 
FlightDEK-D180 Installation Guide    2-1 