Operating Manual Important! Weekly and monthly cleaning required. Register Your free 2 year guarantee today.
IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS APPLIANCE READ ALL INSTRUCTIONS AND CAUTIONARY MARKINGS IN THIS MANUAL AND ON THE APPLIANCE When using an electrical appliance, basic precautions should always be followed, including the following: WARNING THE APPLIANCE AND THE REMOTE CONTROL BOTH CONTAIN MAGNETS. 1. Pacemakers and defibrillators may be affected by strong magnetic fields.
away from traffic area and where it will not be 34. WARNING – This appliance contains a UV-C tripped over. emitter. Do not stare at the light source. 19. To prevent a possible fire, do not use with any 35. If any part is replaced the replacement must opening or exhaust blocked, and keep free of be fitted in its correct position. dust, lint, hair, and anything that may reduce 36. Choking hazard - This remote control unit airflow. Do not put any object into the inlet grill contains a small battery.
Thank you for choosing to buy a Dyson appliance. After registering your free 2 year guarantee, your Dyson appliance will be covered for parts and labour for 2 years from the date of purchase, subject to the terms of the guarantee. If you have any questions about your Dyson appliance, call the Dyson Helpline with your serial number and details of where/when you bought the appliance. Most questions can be solved over the phone by one of our trained Dyson Helpline staff.
Know your humidifier Remote control Loop Cap Handle Chimney Seal Tank Loop release button Base Inlet Piezo UV-C emitter LED display On/ off button Plug 5
Getting started For the best performance place humidifier on the floor in the corner of the room, facing into the centre. It should be at least 1m from any wall. To avoid a cooling effect while humidifying, the unit should be at least 1m from any people. Consider placing near to air conditioning or heating devices to circulate air effectively. 1 Unscrew the cap and fill the tank to the top. Replace the cap and screw until hand tight. Carry by the handle. 6 2 3 Place the tank on top of the base.
4 5 6 Plug into the socket and base. A small blue LED on the back of the appliance lights up to confirm that the appliance has power. Switch ‘ON’. The water treatment procedure automatically starts. Water passes over a UV-C emitter to ensure that it is 99.9% bacteria-free before misting commences. This takes approximately 3 minutes. (During this time humidity targets can be set and fan mode can be switched ON’.) After 3 minutes the appliance will start to humidify.
How to use Fan/ humidity toggle On/off ON/ OFF switches between humidifier and fan modes. Control with airflow and timer buttons. Airflow Controlling the humidity manually Increase airflow. 1 to 10 Increase target humidity. 30 to 70% Decrease airflow. 10 to 1 Decrease target humidity. 70 to 30% AUTO Sleep timer Automatic Mode To set the sleep timer, press and hold the timer button to select the desired time (between 15 minutes and 9 hours).
Refilling the tank When animation sequence shows, the tank is empty. 1 Unplug the appliance and push the button to unlock. Lift the loop amplifier away from tank, then tank away from base. 2 % A Humidity percentage Automatic Mode Remove the cap and fill tank (no other part) to the top with cold tap water. Replace the cap, tank and loop amplifier. Use the handle for easier handling. On/off Press and hold the power button on the appliance to adjust the humidity setting.
Cleaning – important! Cleaning procedures must be routinely followed to ensure that the humidifier continues to operate efficiently. Cleaning regimes are designed to help prevent the build up of scale within the machine, which will be more prominent in hard water areas. Failure to adhere to the cleaning regimes may invalidate the warranty. Make your own cleaning solution + 30 grams of citric acid = 1 litre of water Cleaning solution Other cleaning solutions are available.
Once a week 1 Turn the appliance into standby mode/‘OFF’. Unplug from the mains electricity supply. Wipe over air loop amplifier, paying close attention to the air gaps. Wipe with a lint-free microfibre cloth. 2 Empty the water. Rinse and wipe over all surfaces. Repeat if necessary. 3 Empty the trough and wipe over all surfaces. Small spillages may occur. Do not rinse under the tap or put in the dishwasher. While not dangerous, care should be taken to avoid water entering the inlets.
Once a month (and before/after storage) 1 Turn the appliance into standby mode/‘OFF’. Unplug from the mains electricity supply. Unclip the loop amplifier surround: pull from the lower edge by hand, gently but firmly. 15 mins 4 Empty the water tank. To release the water chimney, twist the dial a quarter of a turn. Lift out. Clean thoroughly by immersing in the citric acid solution for 15 minutes. Rinse and wipe over all surfaces. Repeat if necessary.
Some cleaning chemicals are harmful to the appliance and should not be used. Use of these will invalidate your guarantee. Do not use: Alcohol and strong acid mixes, solvent (acetone) and oil based products, alkali bleach mixes, air fresheners, aroma oils, scented oils, hot water, brushes, abrasive materials, etc. Please do not put in a dishwasher or close to a fire. 2 3 To attach the loop amplifier surround, lie flat and align the surround to the main amplifier.
What do the lights mean? Water treatment The AM10 is treating the water. This takes 3 minutes. When the animation stops, the AM10 will start to humidify. Tank is empty Switch ‘OFF’ and refill. Tilted The base is not level. Please call the helpline. Please call the helpline. If power button flashes 3 times when switching on, check that AM10 has been assembled correctly. 14 AM10 is too cold. Increase room temperature to 5°C or above. If the problem persists, contact the helpline.
Using your humidifier Please read the ‘Important Safety Instructions’ in this Dyson Operating Manual before proceeding. appliance will switch itself ‘ON’ or ‘OFF’ as necessary to maintain that level. The fan will remain running when the target humidity has been reached. Introduction • • This is a cool mist, ultrasonic type of humidifier. Moist air is directed into the room from the loop amplifier. Water passes over a UV-C emitter to ensure that it is 99.9% bacteria-free before misting commences.
Battery replacement CAUTION • • • • • Unscrew the battery compartment on the remote control. Loosen the base and pull to remove the battery. Do not install backwards or short circuit the batteries. Do not attempt to dismantle or charge the batteries. Keep away from fire. Follow battery manufacturers' instructions when installing new batteries (battery type CR 2032). Limited functionality is available without the remote control (see 'Control without the remote').
JN.71733 PN.302491-02-03 09.01.15 www.dyson.
GUARANTEE FORM Serial number / Date of purchase Title / Country of purchase UK ROI Surname First name Address Postcode email Telephone Mobile As a Dyson fan owner, you can hear about Dyson inventions, services and products before anyone else. If it’s okay to contact you, please let us know how we may do this. We sometimes ask other companies (such as market researchers) to contact owners on our behalf. We do this to get feedback on ideas or ask you to try new products and services.