User's Manual

Dyzle BV, 2d Transistorstraat, 1322 CE Almere (NL), Tel.: +31(0)36-5233900, Fax: +31(0)36-5233999
© 2015 Dyzle User Manual for Y-Tag Door Monitor 2.0, version 1.2, February 2015 3
General description of the Y-Tag Door Monitor 2.0
The Dyzle Y-Tag Door Monitor 2.0 is a wireless, water-resistant (IP67) sensor that registers whether a
door is opened or closed. A magnetic door switch is connected to the Y-Tag Door Monitor. The Y-Tag
Door Monitor 2.0 sends the status information every five minutes (open / opened / closed / locked) to
the Y-Gate by way of a wireless connection. The Y-Tag Door Monitor 2.0 checks whether the current
status has changed, every 3 seconds. Changes are logged as an additional interval in the 5-minute
measurement interval. The Y-Gate - the base station - collects measurement data from the Y-Tag(s)
and sends the data to the server.
Product specifications*
Product code
030 1001 002
Accuracy
The Y-Tag checks the state change every 3 seconds. Changes are
logged as an additional interval in the 5-minute measurement interval.
Resolution
3 seconds
Measurement interval
5 minutes
Memory
± 25 days (data backup when the connection to the Y-Gate is lost)
Connectivity to Y-Gate
WIFID, 2.4 GHz (coded)
Connectivity range
100 m (unobstructed)
Power supply
3.6 V DC (lithium battery)
Battery life (guaranteed)
1 year (room temperature)
Operating temperature
-25 °C to +50 °C
Water resistance
IP67 (water-resistant)
Accessories supplied
connecting cable, magnetic door switch
* Refer to the separate product specifications overview for the comprehensive product features.
Safety
Installation of the Y-Tag Door Monitor 2.0 requires general knowledge of safe work practices,
therefore may only be carried out by personnel holding the required operational Safety Certificate and
should also have the necessary knowledge of the spaces, equipment and vehicles that will be
measured for temperature as well as the location where the system is to be installed.
While installing please bear the following in mind: the connection cable may not rest against a hot
pipe. Take the necessary precautions to protect the cable from wear and tear.
Placement and installation
Consult the Dyzle Hardware Installation Manual before proceeding to install the Y-Tag at a stationary
or mobile location, as well as the wiring diagram below for the Y-Tag Door Monitor 2.0.
Connec ondiagram-Doorsensor
Brown
Green
Orange
Black
Yellow
Red
Doorswitch
NormallyOpen
Common
(Black)
n.o.
(Blue)
Brown
Green
Orange
Black
Yellow
Red
Doorswitch
NormallyClosed
Common
(Black)
n.c.
(Brown)
Prosandconsnormallyclosedinstalla on:
+Cable dammagewillbedetected
-Shorterba
erylive