Service manual

TRANSCEIVER PROGRAMMING
4-24
Revised December 2000
Part No. 001-9750-007
CONVENTIONAL GROUP PARAMETERS
(The Group Parameter screen is selected by pressing F6)
Parameter Acceptable Responses Description
Asn Yes, No Specifies if the group will be selectable.
Alpha Tag A-Z, 0-9, etc. Specifies the 10-character alpha tag that is displayed when the group is
selected.
Tx CG None, CG, DCG, IDCG,
EXT
Programs the type of transmit Call Guard squelch for the indicated group
(Section 3.6.2).
CG = Tone (CTCSS), DCG = digital, IDCG = Inverted digital, EXT = External decoder (not supported)
CG Value Tone number or digital
code
If CG was selected, the tone number from 1-38 is entered. If digital was
selected, the digital code is selected. These numbers are listed in Table 4-6.
Rx CG None, CG, DCG, IDCG,
EXT
Programs the type of Receive Call Guard squelch for the indicated group
(Section 3.6.2).
CG Value Tone number or digital
code
If CG was selected, the tone number from 1-38 is entered. If digital was
selected, the digital code is selected. These numbers are listed in Table 4-6.
Send TO (Transmit
Turn-Off Code)
Yes, No If “yes” is programmed, the Call Guard turn-off code is sent when the PTT
switch is released (Section 3.6.2).
Talk-Around Yes, No If “yes” is programmed, transmission is on the receive frequency (Table
3.9.4). “NA” is displayed if talk-around was disabled on the system screen.
Call Light Yes, No Programs if the Call indicator lights when a call is received on that group
(Section 3.6.2).
Horn Yes, No Programs if the horn sounds when a call is received on that group (Section
3.6.4).
Encryption Yes, No Programs if encryption is used on calls received and transmitted on that
group (Section 3.6.12).
Disable-Busy Yes, No Programs if Transmit Disable On Busy feature is active on that group
(Section 3.9.1).
Transmit Disable Yes, No Programs if group is receive-only (Section 3.9.6).
Table 4-4 Conventional System Parameters (Continued)