5100 ES Models II/III Portable Radio Operating Manual April 2009 2-3
Top Panel Controls Section 2 - Controls and Display
2.2 Top Panel Controls
Figure 2.2 Top Panel Controls
Multi-Function Indicator - Indicates the following conditions:
Note This indicator is disabled if the Surveillance mode is programmed (see Section 4.10).
Certain failures encountered during radio startup are indicated by blinking of the Orange
LED. The Type of failure is indicated by the number of times the LED blinks (1 to 10) as
described in
Table 2.2.
Table 2.1 LED Indicators
LED Color LED Duration Description
Red ON Tx: clear
Red 125 ms ON 125 ms OFF Tx: CLEAR with low battery Tx: trunking system
busy
Red 125 ms ON 125 ms OFF 125 ms
ON 750 ms OFF
Rx: Secure Group
Red 750 ms ON 125 ms OFF Rx: Secure individual call
Green ON Rx: clear conventional or trunking
Green 750 ms ON 125 ms OFF Rx: clear individual call
Orange Continuous until Self Test
complete
Self Test state
Orange ON Tx: Secure
Orange 125 ms ON 125 ms OFF Tx: SECURE with low battery
Orange Blinking (1 to 10 times) Startup Failure. See Table 2.2
Emergency
(Option)
Power ON-OFF/
Volume Adj
Channel
Switch
Antenna
Connector
Option
Switch
Button
Multi-Function
Indicator