Service manual
INTRODUCTION
1-2
March 2000
Part No. 001-3139-502
1.2.5 VOTER DIAGNOSTICS MODULE
The Voter Diagnostics Module (VDM), in the 
Switch, is the data communication buffer between the 
SMM and the Voting System (see Section 7). The type 
of data exchanges between the Voting System and the 
VDM pertains to: Memory Read of the voters; 
Receiver Site Enable/Disable; and Alarm/Control 
Information.
1.2.6 VOTER SHELF
Each Voter Shelf (VSH) contains 13 slots for 
cRVM, RVM and CDM modules (see Section 8). The 
maximum total of cRVMs/RVMs is 240, divide this by 
13 slots and the total number of VSHs needed for 
cRVMs/RVMs is 19. The maximum total of CDMs is 
96, divide this by 13 slots and the total number of 
VSHs needed for CDMs is 8. The maximum possible 
total number of VSHs is 27.
1.2.7 VOTER POWER SUPPLY
Each Voter Power Supply (VPS) has the capacity 
to handle two VSHs (see Section 9). The maximum 
total of VSHs is 27, divide this by 2 and the total num-
ber of VPSs needed is 14. There are two VPSs per 
power shelf, therefore, 7 power shelves are the maxi-
mum number per system.
1.2.8 COMPONENTS OF A VOTER SYSTEM
Component Part Number Section
800 MHz RDM 023-3039-580 2
900 MHz RDM 023-3039-590 2
800 MHz RDM 023-3008-231 3
900 MHz RDM 023-2009-231 3
RMM 023-3039-530 4
CDM 023-3039-540 5
RVM 023-3039-520 6
VDM 023-3039-570 7
VSH 023-3039-550 8
VSH Redundant Plate 250-3039-553 9
VSH PS 4-Shelf 250-3039-554 9
VSH PS 2-Shelf 250-3039-555 9
Figure 1-1 LOCAL SITE BLOCK DIAGRAM
Figure 1-2 REMOTE VOTER SYSTEM
IN SWITCH
VOTER SWITCH
CIMMLM
cRVMCDM
RDM
RMM
RRB
32 SITES MAX
IN SWITCH
30 BASE
STATIONS MAX
VOTER SWITCH
3/96 8/240
3/96
30/960
RECEIVERS
CIMMLM
cRVMCDM
RMM
RDM










