User's Manual

INSTALLATION
2-3
May 2000
Part No. 001-2008-204
Table 2-1 OUTPUT VOLTAGES
Voltage Current Wattage
+26.5V 22A 583W
+15V 5A 85W
+5.2V 5A 26W
-5V 1A 5W
Table 2-2 OVER VOLTAGE
Voltage Range
+26.5V +32V to +33V
+15V +16V to +18V
+5.2V +6V to +7V
-5V -6V to -7V
2.6.1 AC INPUT REQUIREMENTS
AC Input Voltage: 100-240V AC
Line Frequency: 50-60 Hz
AC In-rush: 60A maximum
Overall Efficiency: >70% at 100V AC
>80% at 240V AC
Lightning protection: 6kV for < 1ms
Power Factor: >0.97 at full load
Brown Out Voltage: 80V AC
Temperature -30°C - +60°C (full power)
Power factor correction per IEC555. The Power
supply has the following safety agency approvals
pending: UL1950, CSA22.2-950, TUV EN60950
(IEC950)
When the AC input voltage is below 90V AC, the
maximum output power is decreased to keep the input
current constant. If a battery back-up is installed, the
batteries take over when the AC input voltage falls
below 80V AC (dependant on power output).
The AC input connector is an IEC connector
equipped with a locking mechanism.
Figure 2-3 POWER CABLE CONNECTOR AND SCHEMATIC
9
7
12
11
10
8
6
5
4
3
2
1
A
B
C
J2
1
2
3
4
5
6
7
8
9
REPEATER
BACKPLANE
AC FAIL IN
POWER SWITCH
THERMAL SENSOR
+15V
N/C
N/C
-5V
TO
POWER HARNESS
GROUND
+15V
+5V
TO
RFIB
+26.5V
A
B
C
1
2
3
4
5
6
7
8
9
10
11
12
36
9
8
52
1
4
7
J2
BACKPLANE
N/C