User's Manual

Table Of Contents
CONVENTIONAL MODE FEATURES
39
for the “Keypad Programming” function. The keypad
programming mode is indicated by “CHNG ZONE”
and in the display.
Keypad programming allows conventional
channel parameters such as the transmit and receive
frequency, Call Guard squelch code, and encryption
key to be changed. In addition, several conventional
mode timers can be changed. It cannot be used to
reprogram disabled channels or any SMARTNET/
SmartZone/P25 Trunked information.
Figure 5-1 Keypad Programming Menu
Flowchart
5.18.2 MENU DESCRIPTION
A menu system is used to select parameters in the
keypad programming mode. A flowchart showing the
keypad programming mode menu structure is located
in Figure 5-1. When the keypad programming mode is
selected by the Keypad Programming option switch or
menu parameter, the first menu parameter “CHNG
ZONE” is displayed as just described. Press the Up/
Down switch to scroll through the available
parameters which are as follows.
CHNG ZONE
CHNG CHAN
SYS PARMS
CHAN PARMS
Press the F2 (Select) key to select a highlighted
parameter, and press the F1 key from one of the main
menus to exit keypad programming. Pressing it in the
other menus returns to the previous menu. The Up/
Down switch is also used in several menus to scroll
through available selections. Additional information
on this parameters is located in the following sections.
5.18.3 ZONE PASSWORD
NOTE: Make sure that the zone password(s) are not
lost because they cannot be overridden in the field.
The PCConfigure software must be used to display the
lost password or program a new password.
Each zone can be programmed with a password
by the PCConfigure software to prevent unauthorized
reprogramming of zone by keypad programming.
When this password is programmed, it must be entered
before system or channel parameters in that zone can
be changed by keypad programming. The zone pass-
word is programmed in the Zones > Edit Zone screen
of the PCConfigure programmer. This screen is
displayed by clicking the Edit Zone button. A different
password can be programmed for each zone.
When an attempt is made to select a system or
channel parameter in a password protected zone,
“PASSWORD” is flashed. The password is always
eight digits long and is entered using the same proce-
dure as used for the power-up password described in
Section 3.2. After the password is entered, system and
channel parameters for that zone can be reprogrammed
normally.
5.18.4 ZONE CHANGE PARAMETER
The “CHNG ZONE” menu parameter selects the
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for
normal operation.
Zone
Channel
Change
Change
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Tmr On-Off
Squelch Adj*
Chan Spacing*
F1 = Exit/Back
F2 = Select
Up/Down = Scroll
Talk Grp ID**
* Analog Only
** Digital Only
Tx Type Sel***
*** Mixed Mode Ch Only
Key Select
Strapping
Chan Alias