Operator's Manual
Table Of Contents
- SAFETY TRAINING INFORMATION
- FEATURES
- TABLE OF CONTENTS
- OPTION SWITCH FUNCTIONS
- CONTROLS AND DISPLAY
- GENERAL OPERATION
- CONVENTIONAL FEATURES
- Introduction
- Display Mode Selection
- Monitoring Before Transmitting
- Monitor Mode
- Busy Channel Lockout
- Call Guard Squelch
- Penalty Timer
- Conversation Timer
- Repeater Talk-Around
- Power Output Select
- Emergency Mode (Conventional)
- Conventional Mode Scanning
- Priority Channel Sampling
- Placing and Receiving Standard Conventional Calls
- DTMF/ANI Signaling
- Project 25 Mode Features
- Keypad Programming
- Channel Parameter Programming
- SMARTNET/SMARTZONE FEATURES
- MISCELLANEOUS
- INDEX
CONVENTIONAL FEATURES
42
programming mode by turning power off. Do not turn power on again for
a short time so that the radio has time to copy the settings to memory.
Cloning
The cloning mode is used to program one transceiver with another
with identical information. A special cloning cable is required to connect
the transceivers together. To enter this mode, on the master (sending)
radio, press the
# (pound) key with “RAD PARM” displayed. The clone
mode is then indicated by “CLONE?”. To return to “RAD PARM”
without cloning, press the key. To clone a radio, connect the cloning
cable, power up the slave (receiving) radio, and press the
F4 key on the
master (sending) radio. When cloning is successfully completed, “RAD
PARM” is again displayed. Encryption keys are not transferred.
Timer Programming
The menus to program the following timers are accessed by repeat-
edly pressing the
# key with “RAD PARM” displayed. To return to the
previous adjustment, press the key.
TX TMR - Programs the transmit time-out timer (see page 22). Press
the Up/Down select switch to decrement/increment the timer in 15-
second steps (“0” disables it). When the desired value is displayed,
store it by pressing the
F4 key.
PEN TMR - Programs the penalty timer (see page 33). Press the Up/
Down select switch to decrement/increment the timer in 15-second
steps (“0” disables it). When the desired value is displayed, store it by
pressing the
F4 key.
CONV TMR - Programs the conversation timer (see page 33). Press
the Up/Down select switch to decrement/increment the timer in 30-
second steps (“0” disables it). When the desired value is displayed,
store it by pressing the
F4 key.
*
*