User's Manual
Table Of Contents
- SAFETY INFORMATION
- TABLE OF CONTENTS
- SECTION 1 GENERAL
- SECTION 2 CONTROLS AND DISPLAY
- SECTION 3 GENERAL OPERATION
- SECTION 4 RADIOWIDE FEATURES
- SECTION 5 CONVENTIONAL FEATURES
- 5.1 Introduction
- 5.2 Monitoring Before Transmitting
- 5.3 Monitor Mode
- 5.4 Busy Channel Lockout
- 5.5 Call Guard Squelch
- 5.6 Penalty Timer
- 5.7 Conversation Timer
- 5.8 Repeater Talk-Around
- 5.9 Displaying Transmit/Receive Frequency
- 5.10 Emergency Alarm and Call
- 5.11 Conventional Mode Scanning
- 5.12 Standard Conventional Calls
- 5.13 DTMF/ANI Signaling
- 5.14 Single Tone Encoder
- 5.15 Project 25 Mode Features
- 5.16 Keypad Programming
- SECTION 6 SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
- 6.1 Introduction
- 6.2 Analog and Digital Operation
- 6.3 Viewing Unit ID
- 6.4 Standard Group Calls
- 6.5 Private (Unit-To-Unit) Calls
- 6.6 Telephone Calls
- 6.7 Call Alert
- 6.8 Messaging
- 6.9 Sending Status Conditions
- 6.10 Emergency Alarm and Call
- 6.11 Failsoft Operation
- 6.12 SMARTNET/SmartZone/P25 Trunked Scanning Features
- 6.13 Dynamic Regrouping
- 6.14 SmartZone and P25 Trunking Unique Features
- SECTION 7 MISCELLANEOUS
- SECTION 8 DETERMINING AVAILABLE OPTIONS
- SECTION 9 5300 MOBILE FIRMWARE VERSIONS
- SECTION 10 PASSWORD DESCRIPTION
- SECTION 11 SECURE COMMUNICATION (ENCRYPTION)
- INDEX
RADIOWIDE FEATURES
23
channels/talk groups. More information follows on
selecting and editing standard scan lists.
Determining Channels in Standard Scan List
Channels in the conventional standard scan lists
are determined as follows. Channels in the
SMARTNET/SmartZone/P25 Trunked standard scan
lists are indicated only when editing a list (see
“Editing a Standard Scan List”).
1. Enable Standard scanning as described in Section
4.11.2. Also select the scan list if applicable as
described in the following “Selecting a Standard
Scan List” description.
2. Select the desired zone and then scroll through the
channels by rotating the Select switch. When the
displayed channel is in the scan list (scanned
normally), the symbol is displayed next to the
zone number as shown in the following illustration.
Selecting a Standard Scan List
NOTE: only standard scan lists are selectable.
Conventional Operation - The scan list is user
selectable by the SCAN option switch. Refer to
Section 5.11 for more information.
SMARTNET/SmartZone/P25 Trunked
Operation - The scan list can be temporarily
changed if the Scan (List) Select option switch is
programmed. Refer to Section 6.12.3 for more
information.
Editing a Standard
Scan List
If the SCN ED (Scan Edit) option switch is
programmed, standard scan lists can be user edited as
follows (all operating modes). Changes are permanent
(cycling power does not reselect a default condition).
1. Make sure that both standard and radio wide scan-
ning are off (the rotating icon is not indicated in
the right status display). Select a conventional,
SMARTNET/SmartZone/P25 Trunked channel
corresponding to the scan list being edited.
2. Select the scan list edit mode by pressing the SCN
ED option switch. This mode is indicated by a
triangle in the upper left corner of the display (see
Figure 2-3 on page 12.).
3. If applicable, select the list to be edited by rotating
and then pressing the Select switch. The selected
scan list is indicated as “LIST x” as described in the
preceding section. If user programming is disabled
on a list (conventional channels only), “NO EDIT”
is momentarily displayed and it cannot be edited.
4. Select the channel you want to add or delete by
rotating the Select switch. After the last channel in
the current zone is displayed, the first valid channel
in the next zone is displayed and vice versa. Lists are
limited to 256 channels. If an attempt is made to add
more than 256, “LIST FULL” is displayed and a
channel must be deleted before another can be
added.
NOTE: Priority channels can be deleted.
5. If the selected channel is in the scan list (scanned),
the symbol is displayed next to the zone number
as just described. To change the scan list status of
the displayed channel, press the Select switch.
With conventional channels only, if the selected
scan list is programmed with fixed
priority
channel(s), the next press of the Select switch makes
the current channel the priority channel indicated by
“P” in the left status display next to the zone
number. If dual priority channels are used, pressing
the Select switch again makes it the second priority
channel indicated by “2” in the left status display.
Then pressing the Select switch again takes the
channel out of the scan list. Refer to Sections 5.11.3
and 5.11.4 for more information on priority channel
sampling.
6. To exit this mode and save the changes, press the
SCN ED option switch again.
Scan List Indicator
Chnl
No.