User's Manual

Table Of Contents
CONVENTIONAL FEATURES
35
5.16.2 MENU STRUCTURE
A menu system is used to select parameters in the
keypad programming mode. A flowchart showing the
keypad programming mode menu structure is located
in Figure 5-1. When the keypad programming mode is
selected by the PROG option switch, “CHNG ZONE”
is displayed as just described. Rotate and press the
Select switch to scroll through and select the available
parameters which are as follows.
CHNG ZONE
CHNG CHAN
SYS PARMS
CHAN PARMS
Press the Select switch to select the displayed
parameter. Pressing the PROG option switch from one
of the main menus exits keypad programming.
Pressing it from other menus returns to the previous
menu. Refer to the descriptions which follow for more
information.
Figure 5-1 5300 Keypad Programming Menu
Flowchart
5.16.3 ZONE PASSWORD
NOTE: Make sure that the zone password(s) are not
lost because they cannot be overridden in the field.
The PCConfigure software must be used to display the
lost password or program a new password.
Each zone can be programmed with a password
by the PCConfigure software to prevent unauthorized
reprogramming of zone by keypad programming.
When this password is programmed, it must be entered
before system or channel parameters in that zone can
be changed by keypad programming. The zone pass-
word is programmed in the Zones > Edit Zone screen
of the PCConfigure programmer. This screen is
displayed by clicking the Edit Zone button. A different
password can be programmed for each zone.
When an attempt is made to select a system or
channel parameter in a password protected zone,
“PASSWORD” is flashed. The password is always
eight digits long and is entered using the same proce-
dure as used for the power-up password described in
Section 3.2. After the password is entered, system and
channel parameters for that zone can be reprogrammed
normally.
5.16.4 ZONE CHANGE PARAMETER
The “CHNG ZONE” menu parameter selects the
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for
normal operation.
Press the Select switch to select the “CHNG
ZONE” parameter and then scroll through the
programmed zones by rotating that switch. When the
desired zone is displayed, select it by pressing the
Select switch.
5.16.5 CHANNEL CHANGE PARAMETER
The “CHNG CHAN” menu parameter selects the
conventional channel to be reprogrammed. Disabled or
P25 Trunked/SMARTNET/SmartZone channels
cannot be selected. This does not change the channel
selected for normal operation.
Press the Select switch to display “CHAN CHG”
and then scroll through the programmed channels by
rotating that switch. When the desired channel is
displayed, select it by pressing the Select switch.
5.16.6 SYSTEM PARAMETERS
NOTE: If “PASSWORD” is briefly displayed when
attempting to select a parameter, see Section 5.16.3.
The “SYS PARMS” menu parameter selects the
conventional mode timer to be reprogrammed (see
following). Press the Select switch to select “SYS
Change
Change
Channel
Zone
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx (Time-Out) Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Timer On-Off
Squelch Adj*
Ch Spacing*
Tlk Grp ID Sel**
* Analog only ** Digital only
Tx Type Sel***
*** Mixed Mode Ch Only