Operating Manual Part 15
Table Of Contents
- Safety Information
- General
- Controls And Display
- General Operation
- Radio Wide Features
- Conventional Features
- 5.1 Monitoring Before Transmitting
- 5.2 Monitor Mode
- 5.3 Busy Channel Lockout
- 5.4 Call Guard Squelch
- 5.5 Penalty Timer
- 5.6 Conversation Timer
- 5.7 Repeater Talk-Around
- 5.8 Displaying Transmit / Receive Frequency
- 5.9 Emergency Alarm and Call
- 5.10 Conventional Mode Scanning
- 5.11 Standard Conventional Calls
- 5.12 DTMF / ANI Signaling
- 5.13 Project 25 Mode Features
- 5.14 Keypad Programming
- 5.15 Text Messaging
- 5.16 Sending Global Positioning System (GPS) Data
- SMARTNET / SmartZone / P25 Trunked Features
- 6.1 Analog and Digital Operation
- 6.2 Viewing Unit ID
- 6.3 Standard Group Calls
- 6.4 Private (Unit-To-Unit) Calls
- 6.5 Telephone Calls
- 6.6 Call Alert
- 6.7 Messaging
- 6.8 Sending Status Conditions
- 6.9 Emergency Alarm and Call
- 6.10 Failsoft Operation
- 6.11 SMARTNET / SmartZone / P25 Trunked Scanning Features
- 6.12 Dynamic Regrouping
- 6.13 SmartZone and P25 Trunking Unique Features
- 6.13.1 Busy Override
- 6.13.2 Site Trunking
- 6.13.3 Determining Current Site and Searching for a New Site
- 6.13.4 Locking / Unlocking a Site
- 6.13.5 Auto Site Search
- 6.13.6 ZoneFail Site Lock
- 6.13.7 P25 Wide Area Scan
- 6.13.8 Normal P25 and SmartZone Control Channel Hunt
- 6.13.9 Talkgroup Steering through System Access Permissions
- 6.13.10 P25 Wide Area Scan
- 6.14 P25 Trunking Unique Features
- Miscellaneous
- Determining Available Options
- Password Description
- Secure Communication (Encryption)
- Service Information
4-12 5300 ES Series Mobile Radio Operating Manual October 2008
Radio Wide Features
2 Select the desired zone and then scroll through the channels by rotating the Select
switch. When the displayed channel is in the scan list (scanned normally), the
symbol is displayed next to the zone number as shown in the following illustration.
4.13.1.2 Selecting a Priority Scan List
Conventional Operation - The scan list is user selectable by the SCAN option switch.
Refer to Section 5.10.1 for more information.
SMARTNET/SmartZone/P25 Trunked Operation - The scan list can be temporarily
changed if the Scan (List) Select option switch is programmed or by pressing/holding the
scan button. Refer to Section 6.11.2 for more information.
Both of the above operations are also menu selectable.
Note Only Priority scan lists are selectable.
4.13.1.3 Editing a Priority Scan List
If the SCN ED (Scan Edit) option switch is programmed, priority scan lists can be user
edited as follows (all operating modes). This option is also selectable via the menu.
Changes are permanent (cycling power does not reselect a default condition). Proceed as
follows:
1 Make sure that both priority and radio wide scanning are OFF (the rotating icon is
not indicated in the right status display). Select a conventional, SMARTNET/
SmartZone/P25 Trunked channel corresponding to the scan list being edited.
2 Select the scan list edit mode by pressing the
SCN ED
option switch. This mode is
indicated by a triangle in the upper left corner of the display (see Figure 2.3).
3 If applicable, select the list to be edited by rotating and then pressing the Select switch.
A single beep sounds when the switch is pressed (if that option is enabled). The
selected scan list is indicated as “LIST x” as described in the preceding section. If user
programming is disabled on a list (conventional channels only), “NO EDIT” is
momentarily displayed and it cannot be edited.
4 Select the channel you want to add or delete by rotating the Select switch. After the last
channel in the current zone is displayed, the first valid channel in the next zone is
displayed and vice versa. Lists are limited to 256 channels. If an attempt is made to add
more than 256, “LIST FULL” is displayed and a channel must be deleted before
another can be added.
Scan List Indicator
Channel
Number