then selected by simply pressing that switch (password
entry is not required). The keypad programming mode
is indicated by “CHNG ZONE” and a triangle in the
display as follows:
Keypad programming allows conventional
channel parameters such as the transmit and receive
frequency and Call Guard squelch code to be changed.
In addition, several conventional mode timers can be
changed. It cannot be used to reprogram disabled
channels or P25 Trunked and SMARTNET/SmartZone
information.
4.14.1 MENU STRUCTURE
A menu system is used to select parameters to be
changed in the keypad programming mode. Rotate and
press the Select switch to scroll through and select the
available parameters which are as follows. Refer to the
descriptions which follow for more information:
CHNG ZONE
CHNG CHAN
SYS PARMS
CHAN PARMS
Press the Select switch to select the displayed
parameter. Pressing the Keypad Programming option
switch from one of the main menus exits keypad
programming. Pressing it from other menus returns to
the previous menu. A flowchart showing the keypad
programming mode menu structure follows.
Figure 1 Keypad Programming
Menu Flowchart
4.14.2 ZONE PASSWORD
Your transceiver may be programmed so that a
special password must be entered before the system
and channel parameters of a particular zone can be
changed. A different password may be required for
each zone. The first time a system or channel param-
eter of a password-protected zone is selected by
keypad programming, “ENTER PSWD” is flashed.
The eight-digit password must then be entered by
rotating and pressing the Select switch. After the
correct password is entered, the parameters for that
zone can be reprogrammed normally.
4.14.3 ZONE CHANGE PARAMETER
The “CHNG ZONE” menu parameter selects the
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for
normal operation.
Press the Select switch to select the “CHNG
ZONE” parameter and then scroll through the
programmed zones by rotating that switch. When the
desired zone is displayed, select it by pressing the
Select switch.
4.14.4 CHANNEL CHANGE PARAMETER
The “CHNG CHAN” menu parameter selects the
conventional channel to be reprogrammed. Disabled or
P25 Trunked/SMARTNET/SmartZone channels
cannot be selected. This does not change the channel
selected for normal operation.
Press the Select switch to display “CHAN CHG”
and then scroll through the programmed channels by
rotating that switch. When the desired channel is
displayed, select it by pressing the Select switch.
4.14.5 SYSTEM PARAMETERS
NOTE: If “ENTER PSWD” is displayed, the zone
password must be entered as described in the
preceding “Zone Password” description before
parameters can be selected.
The “SYS PARMS” menu parameter selects the
conventional mode timer to be reprogrammed (see
following). Press the Select switch to select “SYS
PARMS” and then rotate that switch to display the
Change
Change
Channel
Zone
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx (Time-Out) Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Timer On-Off
Squelch Adj*
Ch Spacing*
Talk Grp Sel**