Cut Sheet

S
INGLE
-P
HASE
kWh M
ETER
C
LASS
1000
Stand-Alone Configuration
Dim: 6 3/4" H x 5 3/16" W x 3 1/4" D
MMU Style
(Multiple Meter Unit)
Features
Model Numbers
120V, 1-Phase, 2W
(Supplied with (1) split-core current sensor)
E10-212025-JKIT (25 Amp)
E10-212050-JKIT (50 Amp)
E10-2120100JKIT (100 Amp)
E10-2120200JKIT (200 Amp)
120/208-240V, 1- or 2-Phase, 3W
(Supplied with (2) split-core current sensors)
E10-320825-JKIT (25 Amp)
E10-320850-JKIT (50 Amp)
E10-3208100JKIT (100 Amp)
E10-3208200JKIT (200 Amp)
277V, 1-Phase, 2W
(Supplied with (1) split-core current sensor)
E10-227725-JKIT (25 Amp)
E10-227750-JKIT (50 Amp)
E10-2277100JKIT (100 Amp)
E10-2277200JKIT (200 Amp)
Optional Meter Enclosures
Replace “J” in model number with optional
enclosure specification.
Specification M - MMU Configuration
(ex. E10-3208100MKIT)
Specification R - NEMA 4X Raintight Enclosure
(ex. E10-212025-RKIT)
Energy Monitoring Products & Systems
®
Energy Monitoring Products
®
Effective Date: 12/1/2011
(800) 334-3666 - www.emon.com
Direct-read 2-line alpha-numeric LCD display
without multiplier displays accumulative kWh
and “real-time” kW load.
Available in MMU (Multiple Meter Unit) enclosures
containing up to 24 meters in one compact enclosure.
Revenue-grade accuracy.
Patented 0-2 volt output split-core current sensors
promote enhanced safety and accurate remote
mounting of current sensors up to 2,000 feet
from meter without power interruption. (Optional
solid-core sensors available in 100 & 200 amp.)
Parallel up to three (3) sets of current sensors
for cumulative reading.
Current sensor installation diagnostics.
Fixed pulse output.
Non-volatile Memory.
Maintains reading in the event of power failure.
Meter can be used in the following configurations:
- 1-Phase, 2-Wire
- 2-Phase, 3-Wire
For other configurations, contact factory.
Industrial grade JIC steel enclosure (standard) with
padlocking hasp & mounting flanges for indoor
installation. Knockouts: 1 1/16” (3/4” cond.) bottom,
7/8” (1/2” cond.) top.
Optional NEMA 4X polycarbonate enclosure with
padlocking hasp & mounting flanges for indoor/outdoor
installation (stand alone) with one 1 1/16” KO on
bottom of enclosure.
UL/CUL Listed.
Certified by independent test lab to ANSI C12.20
national accuracy standards. (+/- 0.2% from 1% to
100% of rated load.)
California CTEP approved for use with solid-core
current sensors. Listed by the California Energy
Commission.
New York City approved, Con Edison approved for
RSP program.

Summary of content (2 pages)