Specifications

100 E-MU Systems
Sequencer
Pattern Edit Menu
Set the Track to Transmit Externally
If you want to insert
internal program changes
choose Internal and set the
channel number or Multi.
11. Press Home/Enter and scroll to the “Channel Assign” screen.
12. In order for the program change to be transmitted, the track must be
assigned to an External destination (or Both).
13. You must also set the channel to the same channel as the program
change or to Multi. Use MultiA or MultiB if you want to send program
changes on multiple MIDI channels. (MultiA goes out port A; MultiB goes
out port B.)
14. Save the Pattern.
The Conductor Track The conductor track (track 0) allows you to insert tempo and meter changes
anywhere in the pattern. Select the track below track 1 and the first screen
shown below will appear.
To Insert a Tempo Change into the Conductor Track
1. Select the pattern you wish to edit.
2. Press the Pattern Edit button.
3. Press the (-) Track/Channel button until “CT” appears in the track
field.
4. Press the Enter button as prompted by the display to begin editing.
5. Move the cursor to the lower line of the display and select tempo.
T
06 CHANNEL ASSIGN
Channel: MultiA Dest: Ext
T
CT EVENT <-> 003.01.000
C01 tempo: 138 bpm
Conductor Track Screens
T
CT EVENT <-> 003.01.000
C01 meter: 04/4