Specifications

PROPRIETARY DATA: This document contains proprietary data of ABB Inc. No disclosure, distribution (electronic or otherwise),
or other means of dissemination may be made without written permission.
3BUS 208 000 R1301210 Replacement Procedures
Pressure Switch
Complete the following procedures to replace the pressure switch. Refer to
Figure 10-15.
1. At the drive end, remove the bolt that holds the bracket on which the solenoid
and pressure switch rest.
2. After the bracket has been removed, detach the two wires from the top of the
the pressure switch.
3. Unscrew the pressure switch.
4. Install the new pressure switch and make the wiring connections.
5. Reattach the bracket to the drive end of the Scanning Platform.
Figure 10-15 Pressure Switch
Scanning Platform
Drive-side end column
Solenoid
Pressure
Switch