User's Manual
43
External adjustment
RS232C Communication Protocol
BAUD RATE : 19200 bps
Data Length : 8bits
Parity : None
Stop bit : 1bit
Item ASCII Code Data(hex)
1. Power p 00h~01h
2. Input Source i 00h~07h
3. Aspect Ratio r 00h~08h
4. Volume Mute w 00h~01h
5. Volume Control v 00h~64h
6. Screen Mode s 00h~04h
7. Brightness b 00h~64h
8. Contrast k 00h~64h
Item ASCII Code Data(hex)
9. Information f 00h~01h
10. Pip On o 00h~01h
11. Pip Source u 00h~07h
12. Pip Location n 00h~03h
13. Pip Sound set e 00h~01h
14. Pip Mode d 00h~02h
15. Sound Mode y 00h~04h
* Transmission
{Command}{ }{SET ID}{ }{Data}{Cr}
{Commad} To Control Code PDP Monitor
{ } "Space , ASCII Code = 0x20"
{SET ID} You Can Adjust SET ID Setup
Menu of PDP Monitor
{Data} Data Command
Transmit 'FF' data to data
read mode
{Cr} Carriage Return
ASCII Code 0x0d
* Ok Acknowledge
{SET ID}{:}{OK}{x}{Data}{x}
The PDP Monitor set transmits ASCII based on
this format When receiving normal data. At this
time, If the data is data read mode, it indicates
present status data if the data is data write
mode, it returns the data of PC.
* In case set ID is 0, Ack data doesn’t feed back, and
you can adjust all PDP Monitor set.
COMMUICATION PARAMETERS
Command List
Tramsmission / Receiving Protocol List