Installation manual

25
PROGRAMMING
E-TECH ET8 (V4) CONTROL PANEL INSTALLER MANUAL
TAMPER ALARM LOCKOUT
This option programs the Tamper input to Lockout, i.e. cause the Siren & Reset
outputs to sound only once whilst the panel is armed.
PROGRAMMING SEQUENCE:
P60E 4E toggles the option ON and OFF
P60E 4E OFF: Tamper Reset Lockout disabled
P60E 4E ON: Tamper Reset Lockout enabled
P60E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Tamper Reset Lockout enabled
NOTES:
RELATED OPTIONS:
P44E Lockout zones
DURESS TO RESET OUTPUT
Keypad Duress is normally a silent alarm. This option makes the Duress alarm
trigger the Reset output.
PROGRAMMING SEQUENCE:
P60E 5E toggles the option ON and OFF
P60E 5E OFF: No Reset output on Duress alarm
P60E 5E ON: Duress alarm triggers Reset output
P60E 5E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Reset output on Duress alarm
NOTES:
To Disarm with Duress, add any of the
digits 5,6,8 or 9 in front of the User Code
when disarming.
AUTO EXCLUDE ZONES
If a zone is unsealed at the end of Exit Time the panel can either Exclude
(ignore) that zone or immediately alarm.
The panel will give a 2 second Siren burst at the end of Exit Time to indicate
that the panel is armed with a zone/s Auto Excluded. The 2 sec Siren burst can
be disabled by option P62E 7E.
PROGRAMMING SEQUENCE:
P60E 6E toggles the option ON and OFF
P60E 6E OFF: Auto Exclude disabled (instant alarm if unsealed at end of Exit Time)
P60E 6E ON: Auto Exclude enabled (zone is excluded if unsealed at end of Exit Time)
P60E 6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Auto Exclude enabled
NOTES:
RELATED OPTIONS:
P62E 7E Siren burst on Auto Exclude
DISABLE THE DISPLAY
The LED indicators on the keypad can be programmed to blank after 4 minutes
of no keypad use. Any action that causes a beep will restore the display (Use
the button preferably).
PROGRAMMING SEQUENCE:
P60E 7E toggles the option ON and OFF
P60E 7E OFF: Display is always on
P60E 7E ON: Display will blank after 4 minutes
P60E 7E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Display is always ON
NOTES:
On the LCD keypad, the display and
display backlighting will turn off but the
keys backlighting will remain on. The
keypad flap can be closed to reduce
stray light from the keys.
DELAY ARM1 & ARM2 OUTPUTS
The output ARM1 turns on when Area 1 is armed. The output ARM2 turns on
when Area 2 is armed. These outputs can be programmed to turn on instantly
or at the end of Exit Time
ARM1 & ARM2 output s are Pins 3 & 4 on the J3 header on the main board.
PROGRAMMING SEQUENCE:
P60E 8E toggles the option ON and OFF
P60E 8E OFF: ARM1 & ARM2 outputs turn on instantly
P60E 8E ON: ARM1 & ARM2 outputs turn on at end of Exit Time
P60E 8E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: ARM1 & ARM2 outputs are instant
NOTES: