Installation manual

42
PROGRAMMING
E-TECH ET8 (V4) CONTROL PANEL INSTALLER MANUAL
TEST CALL INTERVAL
Test calls to the Central Station can be sent at intervals between 2 and 198
hours in 2 hour increments.
Programmable from 2 to 198 Hours. Enter a value between 1 and 99. (This is
automatically multiplied by 2).
Test Calls must be enabled by option P89E 1E.
PROGRAMMING SEQUENCE:
P83E existing Test Call Interval time is displayed
[ENTER NEW TIME] E new Test Call Interval time is displayed
EXAMPLE: To program daily test calls:
P83E12E
P83E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
84 (=168hrs =7 days)
NOTES:
Enter a value from 1 to 99
RELATED OPTIONS:
P89E 1E Enable Test Calls
P84E Time Before Next Test Call
OPTION No DESCRIPTION DEFAULT NOTE
P83E
P84E
Test Call Interval
Time Before Next Test Call
84
6
x2 = 168hrs (7 days)
x2 = 12hrs
TIME BEFORE NEXT TEST CALL
This option sets the time before the next Test Call and is used to set the
preferred time for Test Calls. Programmable from 2 to 198 Hours. Enter a value
between 1 and 99. (This is automatically multiplied by 2).
EXAMPLES:
A/ New Installation: Set the time before the first test call.
E.g., If you are programming the panel at 5pm and you want test calls to be
sent at 1am. Enter P84E 4E (4 x 2 =8hrs. Therefore 5pm + 8hrs =1am).
B/ Existing Installation: To reset the time that test calls are sent.
E.g., Our example panel is sending test calls at 1am and you want to
change it to 2am. If you are programming the panel at 6pm, enter P84E 4E
(4 x 2 =8hrs. Therefore 6pm + 8hrs =2am).
PROGRAMMING SEQUENCE:
P84E existing Time Before Next Test Call is displayed (See note 3)
[ENTER NEW TIME] E new Time Before Next Test Call is displayed
P84E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
6 (=12hrs)
NOTES:
Enter a value from 1 to 99
If Test Calls are to start immediately, then
the value is set to 0.
The Time Before Next Test Call is
constantly updated. When viewed, the
current value will be displayed (not the
initially entered value).
RELATED OPTIONS:
P89E 1E Enable Test Calls
P83E Test Call interval
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
A
u
t
o
d
i
a
l
l
i
n
g
m
e
t
h
o
d
P
U
L
S
E
D
i
a
l
l
i
n
g
a
l
w
a
y
s
D
T
M
F
d
ia
llin
g
a
lw
a
y
s
.
.
.
.
.
OPTION No DESCRIPTION
P85E Dialling Method
ON
DIALLING METHOD
The dial format is determined by the detected Dial Tone. By default, if no dial
tone is detected after looping the line then the dialler will attempt to dial
regardless alternating between PULSE (Decadic) first and then DTMF dialling.
PROGRAMMING SEQUENCE:
P85E 1E3E turns the option ON
P85E 1E: Auto Dialling (PULSE or DTMF)
P85E 2E: Pulse Dialling always
P85E 3E: DTMF Dialling always
P85E 1E3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
1E, ON: Auto Dialling Method
NOTES:
Only one option is allowed to be ON