E-TECH ET8 ALARM CONTROL PANEL AND DIALLER USER’S MANUAL E-TECH ET8 CONTROL PANEL V4 – USER’S MANUAL, REVISION 1 A$12.
Quality Endorsed Fictional Company ISO9001 E-Tech Security Products Pty Ltd “Australia’s largest designer and manufacturer of high quality security products” HEAD OFFICE: E-Tech Security Products Pty Ltd ABN 000 110 110 12 Security Close Safe Hills NSW 2147 Australia Ph +61 23 9988 7766 Fax +61 23 9988 7765 ET8 V4 INSTALLER MANUAL Revision 1, November 2001 E-TECH SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Document Part Number: 890–265 For product: 100–191 ET8 LE
CONTENTS Features ...................................................................... 4 Introduction ................................................................. 5 Keypad ........................................................................ 6 Keypad Indicators ...................................................... 7 OPERATION by KEYPAD ........................................... 8 Arming ...................................................................... 9 Disarming ...........................
E-TECH ET8 FEATURES • 8 Fully programmable zones • Any combination of hardwire or radio zones • • Comes complete with an AC plug pack and supports a 12V 7Ah battery to maintain systems security under all power supply conditions Full radio supervision • Monitor Mode (Home Mode) • Contact ID Dialler Format • Outputs are separately fused with Automatic Reset Fuses • Ultra-Modern and Impact resistant Housing • Day Mode and Door Chime feature.
INTRODUCTION The E-Tech ET8 micro computer based 8 zone control panel is the heart of your security system to which all your detection devices connect. Arming the system may be done through the keypad or with the use of optional Radio Keys for Arming by remote control from outside the premises. Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises.
KEYPAD The ET8 control panel may be supplied with either the LED keypad (100-192) or the E-Tech LCD Keypad (100-667). The keypad provides important visual and audible indications and is the main interface for operating and programming the ET8 control panel.
KEYPAD INDICATORS LED KEYPAD STATUS LCD KEYPAD ZONES 1~8 OFF ON Zone is sealed Zone is unsealed READY Zone is unsealed, or Power fault or System is Armed, or phone line fault Ready to Arm ARMED Disarmed Armed (AREA 1) ARM2 Disarmed Armed (AREA 2) Disarmed Monitor Mode FLASHING Zone alarm Monitor Mode (LED Keypad only) MAINS Normal Mains Power is off BATTERY Normal The panel’s backup battery is low MEMORY Normal EXCLUDE Normal Zones are excluded TAMPER Normal Tamper alarm
OPERATION This section describes the operation of a USER CODE ASSIGNMENT typical control panel installation. Keep in A User Code assigned to an Area can Arm and Disarm only that Area. User Codes assigned to both Areas will operate both Areas simultaneously. mind that your installation may vary depending on the selected options and equipment. The operating instructions which follow will cover the most common options. Consult your installation company if you require further information.
OPERATION ARMING LCD KEYPAD LED KEYPAD The Ready light must be on Press... or... ARM ARM The Not Ready light must be off ENTER [User Code] Press... ENTER The Armed light will turn on • Leave the premises within the Exit Delay Time • 3 beeps will sound at the end of Exit Delay Time The control panel must be Armed prior to vacating the premises in order to detect intruders. Ensure that the panel is not in Program, Memory or Exclude modes.
OPERATION DISARMING LCD KEYPAD LED KEYPAD Enter the premises through a delay zone Enter the premises through a delay zone Press... [User Code] Press... [User Code] The ENTER Armed light will turn off When you enter the protected premises through a delay zone, the keypad responds with regular beeps* as a reminder to Disarm. You then have your programmed entry delay time to Disarm the panel by entering one of your user codes.
OPERATION MONITOR MODE LCD KEYPAD LED KEYPAD Press... or... MONITOR MONITOR ENTER [User Code] Press... ENTER The Monitor light will turn on • Only the zones which have been programmed by your installer as Monitor zones will be Armed or... [User Code] The MONITOR icon will turn on • Only the zones which have been programmed by your installer as Monitor zones will be Armed Monitor mode allows you to Arm selected zones while others are ignored.
OPERATION KEYPAD PANIC LCD KEYPAD LED KEYPAD Press... or... PANIC PANIC or... PANIC PANIC Both keys together [User Code] ENTER Press... Both keys together or... [User Code] or... ENTER (If Keypad Panic Shortcut has been enabled by your installer) The keypad PANIC function may have been programmed to be either AUDIBLE - activates siren or buzzers, or SILENT - If your system is monitored by a Central Station, sends a PANIC report by dialler.
OPERATION KEYPAD FIRE ALARM LCD KEYPAD LED KEYPAD Press... Press... Sounds the siren (Fire Alarm siren sound) Sounds the siren (Fire Alarm siren sound) 1. If Keypad Fire Alarm has been enabled by your installer Sends a Fire Alarm report by dialler. 1. If your system is monitored by a central monitoring station 2. If Fire Alarm Report has been enabled by your installer 1. If Keypad Fire Alarm has been enabled by your installer Sends a Fire Alarm report by dialler. 1.
OPERATION EXCLUDING ZONES LCD KEYPAD LED KEYPAD ENTER Press... or... The [User Code] Press... or... ENTER Exclude light will turn on [User Code] The EXCLUDE icon will turn on Enter the zone number of the zone/s to be Excluded Enter the zone number of the zone/s to be Excluded [Zone No.] [Zone No.] ENTER [Zone No.] ENTER The zone light of each Excluded zone will turn on Press...
OPERATION VIEWING EVENT MEMORY LCD KEYPAD LED KEYPAD ENTER Press... or... The [User Code] Press... or... ENTER Memory light will turn on The [User Code] MEMORY icon will turn on Press... Press... The most recent event will be displayed The most recent event will be displayed Press... Press... The next most recent event will be displayed The next most recent event will be displayed Press... Press... ...and so on (up to 30 events) ...and so on (up to 30 events) Press...
RADIO KEY OPERATION E-TECH RADIO KEY 3 BUTTON The optional E-Tech Radio Key allows you to Arm, Disarm and activate PANIC. The Radio Key can also Arm Monitor Mode, (if this has been enabled by your installer). ARMING Press the ON button. • The keypad will give 3 beeps. • The outside siren will give 1 ‘chirp’. (If enabled by your installer) • The strobe light will flash briefly DISARMING Press the OFF button. • The keypad will give 3 beeps. • The outside siren will give 3 ‘chirps’.
PROGRAMMING Various system options, as listed below, can be programmed by the user. These options can only be accessed from Program Mode. User Codes may need to be re-programmed if a person has forgotten their code, to give a new user access to the system or to give someone temporary access. User Codes 2-15 can be set as Arm Only Codes. These codes can Arm but cannot Disarm the panel. (Useful for assigning to cleaners, tradesmen etc.
PROGRAMMING PROGRAMMING USER CODES LCD KEYPAD LED KEYPAD Press... [Master Code] ENTER Enters Program Mode. The PROGRAM light will be on. Press... [Option No.] ENTER The two digit option number for the code to be programmed. The existing code (if any) will be displayed. Press... [NEW CODE] ENTER [NEW CODE] ENTER [Master Code] Enters Program Mode. The PROGRAM light will be on. Press... [Option No.] The two digit option number for the code to be programmed.
PROGRAMMING PROGRAMMING THE FOLLOW-ME TELEPHONE NUMBER LCD KEYPAD LED KEYPAD Press... [Master Code] ENTER Enters Program Mode. The PROGRAM light will be on. Press... [Option No.*] ENTER The existing telephone number (if any) will be displayed. Press... [NEW TELEPHONE NUMBER] ENTER The new telephone number will be displayed. Press... [Option No.*] The existing telephone number (if any) will be displayed. Press... [NEW TELEPHONE NUMBER] Press...
MONITORING CENTRAL STATION MONITORING CENTRAL STATION MONITORING The ET8 control panel has an on-board digital dialler which can send detailed alarm messages to a Central Monitoring Station. MONITORED PREMISES TELEPHONE LINE MONITORING STATION The digital messages can include information about the zone or zones which caused the alarm, tamper alarms, low battery or mains failure reports, and it can also (by user number) identify the users who Arm and Disarm the system.
AUDIBLE MONITORING AUDIBLE MONITORING FIXED TELEPHONE MONITORED PREMISES TELEPHONE LINE MOBILE TELEPHONE The ET8 can also be programmed to send audible messages to any telephone or mobile phone. When programmed for audible monitoring, the ET8 calls a pre-programmed number (or numbers) and sounds a series of beeps over the phone. These beeps can identify the zone or zones which caused the alarm and well as several other alarm types.
REMOTE OPERATION OPERATING THE ET8 BY TELEPHONE The ET8 will allow a user to call in to the panel, using a standard DTMF telephone, and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2. To ensure security of operation a user can only carry out remote operations after entering a valid user code. WHAT’S NEEDED: • A telephone with DTMF tones. • A Valid User code programmed in the ET8. • The ET8 to be connected (via Mode 3 socket) to a working telephone line at the installed premises.
REMOTE OPERATION EXAMPLE: ARMING THE ET8 BY TELEPHONE 1. Dial the ET8 telephone number. Listen for one double ring then hang up. 2. Wait 10 seconds, then dial the ET8 telephone number again. The ET8 will answer immediately and gives a 2 second beep followed by low tone. 3. PRESS To prepare the ET8 ( 4. PRESS [User Code] 3 beeps) to authorise the next command ( 5. PRESS to Arm the panel ( 6.
E-TECH ACCESSORIES QUANTUM - 15m passive infra-red detector with selectable pulse count; suitable for domestic and commercial installations. PetAware model available. 100-021 Quantum 100-226 Quantum Plus 100-210 Quantum Dual 100-048 Quantum 360 QUANTUM PLUS - 15m passive infra-red detector with selectable pulse count, temperature compensation and downward looking ‘creep’ zones.
WIRELESS PRODUCTS RADIO ACCESSORIES Ask your installer about the range of E-Tech radio devices for the optional extra convenience of wireless remote control and wireless detection. Operating your E-Tech security system can be as convenient as opening your car door. The E-Tech Radio Key™ provides the benefits of separate ON, OFF and PANIC buttons in a slim, waterproof remote control. * E-Tech radio products require a E-Tech Radio Interface (100-200) to be fitted to the control panel.
TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Zone light on or long beeps when Arming One or more Zone Detection Devices (e.g., PIR, Reed Switch) may be Unsealed Close door or window, find the cause of movement 10 beeps from keypad MAINS light flashing BATTERY light flashing Make sure the plug pack is plugged in The mains power may be off, ...or the panel’s backup battery may be low, and the power point is turned on. ...or a Radio Device battery may be low. Call your installer.
INSTALLATION RECORD INSTALLATION RECORD Date purchased: Date installed: Installation Company: Telephone: E-TECH ET8 ALARM CONTROL PANEL Monitoring Company: ZONES DEVICE TYPE PIR, Reed switch, etc DESCRIPTION P74E Report (dialler) P57E SIREN OUTPUT P56E SONALERT OUTPUT P54E RESET OUTPUT P52E 24 HOUR P51E MONITOR Minutes P46E AREA 2 P29E SIREN RESET TIME P45E AREA 1 Seconds P40E INSTANT Seconds P28E EXIT DELAY TIME P42E HANDOVER P27E ENTRY DELAY TIME 2 ZONE ASSIGNMENT P43E ENTRY DELA
OPERATION SUMMARY OPERATION or... [User Code] ARM [User Code] DISARM ENTER [User Code] x2 [User Code] PANIC or... PANIC or... PANIC PANIC ENTER or... [User Code] Press twice within 4 seconds P69E 5E must be ON Both keys together [User Code] ENTER (Keypad Panic Shortcut must be ON, P62E 4E) ENTER [x] [User Code] KEYPAD DURESS [User Code] ENTER MONITOR MONITOR or... ENTER MONITOR MODE or... Both keys together or... [User Code] (Keypad Panic Shortcut must be ON, P62E 4E) or.